Zone 3). The user must then press a key (1, 2, 4, 5, 7, 8, 0, * or
#) to acknowledge the alarm. If the panel has another alarm to
communicate, it will sound a corresponding number of beeps
for the new zone alarm. The user must then press a key to
acknowledge the signal. When there are no further alarms, the
panel will hang up.
NOTE: The keys 3, 6 and 9 are not valid handshakes.
NOTE: Events not received by the central station due to an
FTC will not be transmitted via the Private Line format.
Post Dial Wait for Handshake Timer . . . . . . . . . Section [161]
Scantronics and Sur-Gard 4-8-1 Formats
These are DTMF formats that send reporting codes as:
One 4-digit account code
Eight 1-digit reporting channels (event code)
One 1-digit status channel
The software automatically generates a code for the event
based on the programming of the call direction groups.
1
2
3
aaaa
x
x
x
Account
Code
When you program the reporting codes for zones and events
(programming sections [320]-[353]), program them in the for-
mat XY, where:
X= channels 1-8
Y= event code (0-9).
NOTE: If your central station uses a Scantronics 5100 receiver,
only program numbers from 1 to 6 for the event code.
Example: If you program the zone 3 alarm reporting code as
[31], the panel will send event code 1 in channel 3. The panel
will send the number 5 for each of the other channels, so that
the event code will look like:
5 5 1 5 5 5 5 5
The panel will send the status code (i) based on the status of
the zone:
7 = Alarms, Tampers, Restorals, Openings & Closings
8 = Trouble or Trouble Restoral
9 = Test Transmission.
Example: If there is an alarm on Zone 3 the panel will send:
a a a a
5 5 1 5 5 5 5 5
To disable communication for specific events, program '00' or
'FF' for the reporting code.
The Scantronics and Sur-Gard 4-8-1 formats work similarly.
Select one or the other depending on the type of receiver in
use at the central station.

5.10 Downloading

The required downloading software is DLS-3 version 1.2
and up.
Downloading allows you to program the entire control panel
via a computer, a modem and a telephone line. All functions,
features, their changes and status – such as trouble condi-
tions and open zones – can be viewed or programmed
through downloading.
NOTE:Downloading is always enabled for six hours each time
the panel is powered up, unless the User Can Enable DLS
Window option is disabled
The panel will answer calls for downloading when the pro-
grammed Number of Rings is heard by the panel.
20
Channels
4
5
6
7
8
x
x
x
x
x
Event
Status
Code
Code
7
If the Answering Machine/Double Call option is enabled (or
during the first six hours after power up), the panel will answer
incoming calls for downloading in the following manner:
1. The panel hears one or two rings then misses a ring.
2. At this point the panel will start a the double-call timer.
3. If the panel hears another ring before the Answering
Machine Double-Call Timer expires, it will answer on the
first ring of the second call.
The panel will immediately go on line and begin downloading.
If the Call-Back option is enabled, the panel and the com-
puter will both hang up. The panel will then call the Down-
loading Computer's Telephone Number and wait for the
computer to answer. Once the computer answers, download-
ing will begin.
If the User Enabled DLS Window option is ON, the user can
activate the downloading feature for a set period of time by
entering [*][6][Master Code][5].
If the Full 6-hour User Enabled DLS Window option is
enabled, when the user opens the DLS window with
[*][6][Master code][5], the DLS window will remain open for
six hours. The DLS window will remain open after a successful
hang-up from a downloading call. If the One Time 1-hour
i
User Enabled DLS Window option is enabled, when the user
opens the DLS window with [*][6][Master code][5], the DLS
window will stay open for one hour, and will close after a suc-
cessful hang-up from a downloading call.
After six hours, the panel will not answer incoming calls unless
the Answering Machine/Double Call option is enabled, or the
Number of Rings is programmed to be more than [0].
If the User Initiated Call-Up option is enabled, the user can
have the panel initiate a call to the downloading computer by
pressing [*][6][Master Code][6].
The Download Access Code and Panel Identifier Code are
for security and proper identification. Both the panel and the
computer file should contain the same information pro-
grammed before attempting to download.
The time to complete a successful download can be significantly
reduced with the use of the PC-LINK. This adaptor makes it pos-
sible to perform on-site downloading. To Initiate Local Down-
loading
via
Code][499][Installer's Code][499]. All keypads will be busy for
the duration of the PC-LINK connection. The status LEDs will dis-
play the current system status on the keypad where the PC-LINK
was initiated. For more information on connecting the PC-LINK,
refer to your "PC-LINK Download Kit Instruction Sheet".
NOTE: When a zone status upload is performed through
PC-LINK, the information uploaded may not be accurate. For
more information, refer to your DLS-3 manual.
NOTE:When uploading labels from LCD keypads, only labels
from the LCD keypad assigned to slot 8 will be uploaded.
Answering Machine/Double Call . . . . . . . . Section [401]: [1]
User Enable DLS Window . . . . . . . . . . . . . Section [401]: [2]
Call-Back . . . . . . . . . . . . . . . . . . . . . . . . . . Section [401]: [3]
User-initiated Call-up enabled/disabled . . . Section [401]: [4]
One/Six Hour User-enabled DLS Window . Section [702]: [7]
Downloading Computer's Telephone Number . Section [402]
Downloading Access Code . . . . . . . . . . . . . . . Section [403]
Panel Identification Code . . . . . . . . . . . . . . . . . Section [404]
Answering Machine Double Call Timer . . . . . . Section [405]
Number of Rings to Answer On . . . . . . . . . . . . Section [406]
Initiate Local Downloading (PC-LINK) . . . . . . . Section [499]
the
PC-LINK,
enter
[*][8][Installer's

Advertisement

Table of Contents
loading

Table of Contents