DSC Power632 PC1555 Instruction Manual
Hide thumbs Also See for Power632 PC1555:

Advertisement

W A R N I N G
This manual contains information on limitations regarding product use and function and
information on the limitations as to liability of the manufacturer.
The entire manual should be carefully read.
I n s t r u c t i o n
M a n u a l
PC1555/PC1555MX
Software Version 2.3

Advertisement

Table of Contents
loading

Summary of Contents for DSC Power632 PC1555

  • Page 1 W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. I n s t r u c t i o n M a n u a l PC1555/PC1555MX Software Version 2.3...
  • Page 2: Limited Warranty

    LIMITED WARRANTY Digital Security Controls Ltd.’s liability for failure to repair the prod- Digital Security Controls Ltd. warrants the original purchaser that uct under this warranty after a reasonable number of attempts will be for a period of twelve months from the date of purchase, the prod- limited to a replacement of the product, as the exclusive remedy for uct shall be free of defects in materials and workmanship under normal use.
  • Page 3 General System Operation Your security system is made up of a DSC control panel, one or more keypads and various sensors and detectors. The control panel will be mounted out of the way in a utility closet or in a basement. The metal cabinet contains the system electronics, fuses and stand-by battery.
  • Page 4 System Information Fill out the following information for future reference and store this manual in a safe place. Access Codes Your Master Code is: __________________________________________ Additional Access Codes: 01 __________________ 09 ____________________ 17 ____________________ 25 ________________ 02 __________________ 10 ____________________ 18 ____________________ 26 ________________ 03 __________________...
  • Page 5 ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ [F] FIRE __________________________________________ [A] AUXILIARY ____________________________________ [P] PANIC ________________________________________ The Exit Delay Time is ________ seconds.
  • Page 6 Access Codes Access codes are used to arm and disarm the system. There are 37 access codes available: 1 master code, 32 regular access codes, 2 duress codes and 2 supervision codes. Ask your installer for more information on using the duress and supervision codes. Only the Master Code can be used to program additional security codes and to change other system features as well as to arm and disarm the security system.
  • Page 7 Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will begin. To arm in the Away mode, enter your access code and exit the premises through a designated Exit/ Entry door.
  • Page 8 Disarming the System Disarming from an LED Keypad: Enter the premises through a designated Exit/Entry door. Entering by any other door will sound an immediate alarm. As soon as the Exit/Entry door is opened, the keypad will beep to indicate that the system should be disarmed.
  • Page 9 If an Alarm Sounds Fire Alarm If your system has been installed with fire detectors and the alarm sounds in a pulsing mode, follow your emergency evacuation plan immediately (see “Fire Escape Planning” on page 15). Intrusion Alarm If an intrusion alarm sounds, indicated by a continuous Bell or Siren, the alarm may be silenced by entering your access code.
  • Page 10 PC5508Z LED Keypad Memory Light Upon disarming, if an alarm has occurred while the system was armed, the Memory light will turn ON (See “Disarming the System” on page 6). Bypass Light If the Bypass light is ON, one or more zones are bypassed (See “Zone Bypassing”...
  • Page 11 LCD5500Z Keypad LCD5501Z Keypad Emergency Keys (All Keypads) The Liquid Crystal Display (LCD) displays Press both * Keys for two seconds to send a prompts and system information on two 16 FIRE transmission. character lines. Press both * Keys for two seconds to send an If “<...
  • Page 12 Programming codes from an LCD Keypad: Master Code Press the [✱] key to enter the function list. Scroll (< >) to... Press [5] or [✱]. The display will read... Enter your current Master Code. The display will read... “40P” represents the Master Code. Press the [✱] key to indicate that you wish to program the Master Code.
  • Page 13 Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones that are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made. Bypassed zones will not cause an alarm.
  • Page 14 To view troubles from an LED Keypad: A trouble will be indicated by the Trouble light, which will remain ON until the trouble condition is cleared. If you cannot determine the cause of the trouble condition, contact your installer for assistance. To view the type of trouble condition, press [✱][2].
  • Page 15 Testing Your System Alarm Test The Alarm Test provides two-second tests of the keypad sounder and bell or siren. Begin with the panel in the Ready state. ✱ From an LED keypad, Enter [ ][6][Master Code][4] then press [#] to return to the Ready state. ✱...
  • Page 16 To activate the door chime from an LCD Keypad: ✱ Press [ ] to enter the function list, then scroll to find... ✱ Press [ ] or [4] to enable or disable the Door Chime feature. Press [#] to return to the Ready state.
  • Page 17 Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly. It is thus very important that a family escape plan be developed and rehearsed. 1. Every family member should participate in developing the escape plan. 2.
  • Page 18 made through standard plugs and telephone company provided jacks, or FCC COMPLIANCE STATEMENT equivalent, in such a manner as to allow for easy, immediate disconnection CAUTION: Changes or modifications not expressly approved by Digital of the terminal equipment. Standard jacks shall be so arranged that, if the Security Controls Ltd.
  • Page 19: Warning Please Read Carefully

    I I I I I Smoke Detectors WARNING Please Read Carefully Smoke detectors that are a part of this system may not properly alert occupants of a Note to Installers fire for a number of reasons, some of which follow. The smoke detectors may have been improperly installed or positioned.
  • Page 20 © 2001 Digital Security Controls Ltd. Toronto, Canada Printed in Canada 29004474 R001...

This manual is also suitable for:

Power632 pc1555mx

Table of Contents