Performing A Raid Array Rebuild; Looking Up Changed Mac / Wwn Addresses; Looking Up Mac Addresses - Fujitsu PRIMERGY CX2550 M2 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic software procedures

5.2.13 Performing a RAID array rebuild

After replacing a hard disk drive that has been combined into a RAID array,
RAID rebuild will be performed completely unattended as a background
process.
Ê Ensure that the RAID array rebuild has started normally. Wait until the
progress bar has reached at least one percent.
Ê Inform the customer about the remaining rebuild time, based on the
displayed duration estimate.
Figure 15: Progress bar (RAID array rebuild)
V
CAUTION!
The system is now operational, however, data redundancy will not be
available until the RAID array rebuild is complete. Depending on the hard
disk drive capacity the overall process can take up to several hours, in
some cases even days.
I
You may notice a slight performance impact during rebuild.

5.2.14 Looking up changed MAC / WWN addresses

When replacing a network controller, the MAC (Media Access Control) and
WWN (World Wide Name) addresses will change.
I
In addition to the procedures described below, MAC / WWN addresses
can also be found on the type label attached to a network controller or
system board.

5.2.14.1 Looking up MAC addresses

Ê Enter the ServerView iRMC web frontend.
Ê Select the System Information menu.
80
Upgrade and Maintenance Manual
CX2550 M2

Advertisement

Table of Contents
loading

Table of Contents