Installing and removing
4.2 Information on mounting
Explosion hazard
Do not disconnect equipment when a flammable or combustible atmosphere is present.
Additional notes
Use only approved components
If you use components and accessories that are not approved for SIMATIC NET devices or their
target systems, this may violate the requirements and regulations for safety and
electromagnetic compatibility.
Only use components approved for the SIMATIC NET devices.
NOTICE
Warming and premature aging of the IE switch due to direct sunlight
Direct sunlight can heat up the device and can lead to premature aging of the IE switch and its
cabling.
Provide suitable shade to protect the IE switch against direct sunlight.
Note
During installation and operation, keep to the installation guidelines and safety notices
described in this document and in the system manuals "Industrial Ethernet / PROFINET Industrial
Ethernet" and "Industrial Ethernet / PROFINET passive network components".
You will find information on the system manuals in the section "Introduction (Page 3)", under
"Further documentation".
4.2

Information on mounting

The devices can be installed in the following ways:
• Installing in an Extension unit box
• DIN-rail mounting
Installation clearances
When mounting on DIN rail, observe the following minimum clearances so that the
convection ventilation of the device is not blocked:
• Below at least 10 cm
• Above at least 10 cm
34
WARNING
CAUTION
Operating Instructions, 02/2023, C79000-G8976-C676-01
SCALANCE XF-200G