CHECK THE INSTALLATION STATUS
5) Operation rate changing table of dispenser heater
Set item
Dispenser Heater Rate
Reference
Value
Setting value
FZ compartment
Code
0
[Sub-Heater] + 20% operation( up to 100% )
1
[C-Fan] C-Fan turn on after 10 minutes delay when Comp On
(It operates only external temperature 12℃ ~39 ℃ )
6) Temperature changing table of freezer compartment (When the Freezer works as a Fridge Mode)
Set item
Reference
Value
Setting value
FZ Compartment
compensation
code
0
1
2
3
4
5
6
7
This document cannot be used without Samsung's authorization.
Fridge Room 7-SEG
19
Rate change
+0.0%
Freezer Temp Shift
Fridge Room 7-SEG
31
Temp.
0.0℃
-0.5℃
-1.0℃
-1.5℃
+0.5℃
+1.0℃
+1.5℃
+2.0℃
83