PRODUCT SPECIFICATIONS
Items
Model
Defrost Heater (FRE)
Defrost Heater (REF)
Dispenser Heater
French Heater
Water Pipe Heater
Water Tank Heater
Ice Maker Heater
Ice Room Heater
Protector of
FRE/REF Defrost
Heater
Motor BLDC (FRE)
Motor BLDC (REF)
Motor BLDC (CIRCUIT)
This document cannot be used without Samsung's authorization.
Heated at F Defrost
Heated at R Defrost
Heated at Case Dispenser
(Parallel with French Heater)
Heated at French
Heated at Water Pipe
-
-
-
Bimetal
Thermal Fuse
Specification
RF57A5032*
RF57A5232*
AC 120V, 230W / AC 230V, 230W
AC 115V, 100W / AC 230V, 100W
AC 120V, 2W / AC230V, 2W
AC 120V, 10W / AC 230V, 10W
AC 125V, 6 or 10A(AC 250V, 3 or 5A)
OFF : 140°F(60℃). ON : 104°F(40℃)
AC 250V, 10A, OFF : 228.2~230℉(109~110 ℃)
DC12V, BLDC(Box Fan, 92mm), 1.2W
DC12V, BLDC(Box Fan, 92mm), 1.2W
DC12V, BLDC(C160N, Φ160), 1.32W