11.1 Diagnosis codes (continued)
11.1.1

Setting the heating partial load

The heating partial load of the Vaillant ecoTEC plus boiler is
factory set to "auto". This means that the boiler independ-
ently determines the optimum heating output depending on
the current heat demand of the system. A setting is nor-
mally no longer required. If you still want to set a fixed
maximum heating partial load, you can set a value under
diagnosis code "D.000", which equates to the boiler output
in kW.
11.1.2
Setting pump overrun time and pump
operating mode
The pump overrun time for the heating mode is set at the
factory to a value of 5 minutes. You can set the pump over-
run time under diagnosis code "D.001" within the range of
1 minute to 60 minutes. You can set a different pump oper-
ating mode under diagnosis code "D.018". Here you have
the choice between Eco and Comfort.
Comfort (continuously operating pump)
The internal pump is switched on when the heating flow
temperature is not at "Heating off"(¬ Operating instruc-
tions) and the heating requirement is enabled via an exter-
nal controller.
Installation and maintenance instructions ecoTEC plus 0020116700_01
Adapting the boiler to the heating installation
Adjustable values
No reception
Reception
Synchronised
Valid
Delete fault list
PCB (BMU)
Display(AI)
actoSTOR(APC)
HBI/VR34
Reset all adjustable parameters to factory setting
Display xx.yy
xx = Coding resistor 1 in cable harness for output
range:
08 = VU 612, VU 615, VU 618, VUW 824
09 = VU 624, VUW 831
10 = VU 630
11 = VU 637, VUW 837
yy = Coding resistance 2 on PCB for gas group:
02 = P-Gas
03 = H-Gas
11
Factory
Your own
setting
setting
Not adjustable
Not adjustable
Not adjustable
53