Operating Levels; Operating; Starting Up The Product; Adjusting The Target Cylinder Temperature - Vaillant flexoTHERM VWF 5x Operating Instructions Manual

Table of Contents

Advertisement

5 Operating

4.10 Operating levels

The product has two operating levels.
The operating level for the operator shows
the information and offers set-up options
that do not require any special prior know-
ledge.
The operating level for the competent per-
son is protected by a code.
Overview of the operator's operating level
(→ Page 16)
5 Operating

5.1 Starting up the product

Only start up the product once the cas-
ing has been completely closed.
5.2 Adjusting the target cylinder
temperature
In order to achieve energy-efficient hot
water generation predominantly from the
energy extracted from the environment,
the factory setting for the desired hot water
temperature must be adjusted on the sys-
tem controller.
To do this, adjust the cylinder set target
temperatures (Desired DHW circuit
temperature) to between 50 and 55 °C,
for example.
Depending on the source of energy
obtained from the environment,
hot water output temperatures of
between 55 and 62 °C are reached.

5.3 Yield indicator

Displays the environmental energy yield as
a cumulative value for a period of a day,
a month and the total for the heating, hot
water generation and cooling modes.
Displays the working figure for a period of
a month and the total for the heating and
hot water generation modes. The work-
ing figure is the ratio of thermal energy
generated to the operating current used.
12
Monthly values may vary considerably
since, for example, in the summer only
hot water generation is used. A large num-
ber of factors influence this estimate, e.g.
the type of heating installation (direct heat-
ing mode = low flow temperature or indir-
ect heating mode via buffer cylinder = high
flow temperature). This figure may there-
fore deviate by up to 20%.
The working figures only record the power
consumption of internal components, not
of external components such as external
heating circuit pumps, valves, etc.

5.4 Displaying the Live Monitor

Menu → Live Monitor
– You can use the Live Monitor to display
the current status of the product.
5.5 Displaying the building circuit
pressure
Menu → Live Monitor→ Building circuit
pressure
– Current filling pressure of the heating
system
5.6 Displaying the environment
circuit pressure
Menu → Live Monitor→ Environment
circuit pressure
– Current filling pressure in the environ-
ment circuit
5.7 Reading the operating
statistics
Menu → Information → Heating op.
hours
Menu → Information → DHW operating
hours
Menu → Information → Cooling op.
hours
Menu → Information → Total operating
hours
Operating instructions flexoTHERM 0020213396_00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Flexotherm vwf 19x/4

Table of Contents