How To Install The Pump And Bell Housing Assembly - Terex Genie S-40 XC Service And Repair Manual

Hide thumbs Also See for Genie S-40 XC:
Table of Contents

Advertisement

Service and Repair Manual
Engines
How to i nstall the Pum p and Bell H ousing Ass embly
How to Install the Pump and Bell
Housing Assembly
1
Install the pump and bell housing assembly.
Deutz models: Torque the bell housing
mounting bolts labeled "C" in sequence to
28 ft-lbs / 38 Nm. Then torque the bell
housing mounting bolts labeled "C" in
sequence to 40 ft-lbs / 54 Nm.
Ford models: Torque the bell housing
mounting bolts labeled "A" and "B" in
sequence to 28 ft-lbs / 38 Nm and the
mounting bolts labeled "C" to 49 ft-lbs / 66
Nm. Then torque the bell housing mounting
bolts labeled "A" and "B" in sequence to 40 ft-
lbs / 54 Nm and the mounting bolts labeled
"C" to 70 ft-lbs / 95 Nm.
Perkins models: Torque the bell housing
mounting bolts labeled "B" in sequence to
28 ft-lbs / 38 Nm and the mounting bolts
labeled "A" to 49 ft-lbs / 66 Nm. Then torque
the bell housing mounting bolts labeled "B" in
sequence to 40 ft-lbs / 54 Nm and the
mounting bolts labeled "A" to 70 ft-lbs / 95
Nm.
Component damage hazard.
When installing the pump, do not
force the pump coupler into the
flexplate or damage to the pump
shaft seal may occur.
Component damage hazard. Do
not force the drive pump during
installation or the flex plate teeth
may become damaged.
58
S
-40/45 XC
• S
-40/45 HF • S
®
®
Deutz Models D2011L03i
Deutz Models D 2.9 L4, TD 2.2 L3
Ford Models
-40/45 TraX
®
February 2023
Part No. 1286829GT

Advertisement

Table of Contents
loading

Table of Contents