DSC OPERATION
■ DSC Settings (Continued)
D DSC data output
When receiving a DSC call, this
function makes the transceiver send the
DSC data from its NMEA Output port to
an external device.
All Stations: O utputs the call from any
vessel from the NMEA
Output port.
Station List: O utputs the call from
any vessels listed on the
Individual ID screen.
OFF:
D oes not output any call
to an external device
(Default).
62
D Setting the Alarm Status
• Safety
• Routine
Select whether or not to sound an alarm
when receiving a Safety or Routine
DSC call.
1.
Push [MENU].
2. S elect the item, then push [ENT].
( D SC Settings > Alarm Status >
Safety)
( D SC Settings > Alarm Status >
Routine)
(Example: Safety)
3. Select the option, then push [ENT].
• On: A larm sounds. (Default)
• Off: A larm does not sound.
4.
P ush [MENU] to return to the Main
screen.
• Warning
Select whether or not to sound an alarm:
• When no MMSI code is entered.
• W hen the position data has not been
updated for 10 minutes.
• W hen the position data has not been
manually updated for 4 hours.
• A fter the invalid GPS position data or
manually entered position data has not
been updated for 23.5 hours.
1.
Push [MENU].
2. S elect "Warning," then push [ENT].
( D SC Settings > Alarm Status >
Warning)
Rotate
+
Push
3. Select the option, then push [ENT].
• On: Alarm sounds. (Default)
• Off: Alarm does not sound.
4.
P ush [MENU] to return to the Main
screen.
Rotate
+
Push