A A c c c c e e s s s s o o r r i i e e s s

Document Pack Contents

Item
Qty.
Description
1
1
Condensate Drain Tube Assembly
2
1
Inlet Vent
(a)
3
1
Inlet Vent Gasket
4
1
Outlet Vent Assembly
5
1
Outlet Vent Gasket
6
6
Screws
7
1
Condensate Trap Grommet
8
1
Plug — Condensate/Gas
9
1
Plug — Electrical
10
2
Grommet — Condensate/Gas
11
1
Installer's Guide
12
1
Service Facts
13
1
Owner Guide
14
1
Limited Warranty
15
1
2" to 3" Coupling — CPL00938
16
2
Brand labels
(c)
(a)
3" inlet vent supplied with A952V120DU5SAB and A952V120DD5SAB only. 2" inlet vent supplied with all other models.
(b)
Supplied with A952V120DU5SAB and A952V120DD5SAB only
(c)
Place appropriate brand label below the warning label on the front panel using stencil marks as guides.
10
Installer's Guide
Up ow/Horizontal and Down ow
Gas-Fired, Direct/Non-Direct Vent, 2–Stage
Condensing Variable Speed Furnaces
U U p p f f l l o o w w , , C C o o n n v v e e r r t t i i b b l l e e t t o o
D D o o w w n n f f l l o o w w O O n n l l y y
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r
A952V040BD3SAB
H H o o r r i i z z o o n n t t a a l l L L e e f f t t
A952V060BD3SAB
A952V040BU3SAB
A952V080BD4SAB
A952V060BU3SAB
A952V100CD4SAB
A952V060BU4SAB
A952V100CD5SAB
A952V080BU4SAB
A952V120DD5SAB
A952V080CU5SAB
A952V100CU4SAB
A952V100CU5SAB
A952V120DU5SAB
N N o o t t e e : : Graphics in this document are for
representation only. Actual model may differ in
appearance.
!
CAUTION
COIL REQUIREMENT!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
88-A952V001-1D-EN
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit. See Installer's Guide for more information.
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
8 8 8 8 - - A A 9 9 5 5 2 2 V V 0 0 0 0 1 1 - - 1 1 D D - - E E N N
May 2020
(b)
88-A952V001-1D-EN