Document Pack Contents; Part List - Trane S9V2B040U3PSC Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

A A c c c c e e s s s s o o r r i i e e s s

Document Pack Contents

Item
Qty.
Description
1
1
Condensate Drain Tube Assembly
2
1
Inlet Vent (2"- ADP01586 and 3" -
ADP01587)
(a)
3
1
Inlet Vent Gasket
4
1
Outlet Vent Assembly
5
1
Outlet Vent Gasket
6
6
Screws
7
1
Condensate Trap Grommet
8
1
Plug — Condensate/Gas
9
1
Plug — Electrical
10
2
Grommet — Condensate/Gas
11
1
Installation, Operation, and
Maintenance
12
1
Owner Guide
13
1
Limited Warranty
14
1
2" to 3" Coupling — CPL01544
3" inlet vent supplied with S9V2D120U5PS and S9V2D120D5PS only. 2" inlet vent supplied with all other models.
(a)
(b)
Supplied with S9V2D120U5PS and S9V2D120D5PS only.

Part List

Igniter
Flame Sensor
In-shot Burner(s)
Gas Valve
10
Installation, Operation, and Maintenance
Up ow/Horizontal and Dedicated Down ow
Gas-Fired, Direct/Non-Direct Vent, 2–Stage
Condensing Variable Speed Furnaces
U U p p f f l l o o w w , , C C o o n n v v e e r r t t i i b b l l e e t t o o
D D o o w w n n f f l l o o w w O O n n l l y y
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t o o r r
S9V2B040D3PSC
H H o o r r i i z z o o n n t t a a l l L L e e f f t t
S9V2B060D3PSC
S9V2B040U3PSC
S9V2B080D4PSC
S9V2B060U4PSC
S9V2C100D5PSC
S9V2B080U4PSC
S9V2D120D5PSC
S9V2C080U5PSC
S9V2C100U5PSC
S9V2D120U5PSC
WARNING
FIRE HAZARD!
Failure to follow this Warning could result in property damage, severe personal
injury, or death.
This Warning applies to installations with a ammable refrigeration system.
N N o o t t e e : : Graphics in this document are for
The furnace must be powered except for service. The furnace shall be installed
and connected according to installation instructions and wiring diagrams that
are provided with the evaporator coil.
CAUTION
!
COIL REQUIREMENT!
Failure to follow this Caution could result in property damage or personal injury. 4GXC* and
4MXC* coils installed on upflow furnaces in vertical, horizontal left, or horizontal right
orientations without a factory installed metal drain pan shield must use a MAY*FERCOLKITAA
kit. Coils installed on upflow furnaces must have drain pans that are suitable for 400° F
(205°C) or have a metal drain pan shield. Downflow furnaces do not require a metal drain pan
shield or the use of the MAY*FERCOLKITAA kit.
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
S S 9 9 V V 2 2 - - S S V V X X 0 0 0 0 1 1 - - 1 1 B- - E E N N
September 2023
(b)
Inducer Assembly
Blower Motor
Blower Wheel
IFC (Integrated Furnace Control)
representation only. Actual
model may differ in appearance.
Pressure Switch(es)
Main Thermal Limit
Roll-Out Switch(es)
Reverse Air Switch(es)
S9V2-SVX001-1B-EN