Accessories; Document Pack Contents - Trane S8X1A026M2PSAB Installer's Manual

Upflow/downflow/horizontal gas-fired, 1–stage and 2–stage induced draft furnaces with high efficiency motor
Hide thumbs Also See for S8X1A026M2PSAB:
Table of Contents

Advertisement

Accessories

Table 1. Accessories
Model Number
BAYHANG
BAYLIFTB
BAYLIFTC
BAYLIFTD
BAYBASE205
BAYSF1165AA
(a)
BAYSF1255BA
FLRSF1255
BAYVENT600A
BAYVENT800B
BAYSWT20AHALTAA
BAYSWT21AHALTAA
BAYSWT22AHALTAA
BAYSWT14AHALTAB
BAYSWT15AHALTAA
BAYSWT16AHALTAB
BAYSWT17AHALTAA
BAYSWT18AHALTAA
BAYSWT19AHALTAA
BAYSWT23AHALTAA
BAYSWT24AHALTAA
BAYLPSS400*
BAYLPSS410A
PIP02095
(a)
Airflow greater than 1600 CFM requires dual returns

Document Pack Contents

Item
Qty.
Description
1
1
Plug — Gas
2
1
Installer's Guide
3
1
Service Facts
4
1
Owner Guide
5
1
Limited Warranty
6
2
Tinnerman Clips
Note: Tinnerman Clips should be
kept with unit and are used
if the door panel flange hole
(s) becomes stripped.
8
Description
Horizontal Hanging Kit
Dual Return Kit (B size extension)
Dual Return Kit (C size extension)
Dual Return Kit (D size extension)
Downflow Subbase
1" SlimFit Box with MERV 4 Filter
1" SlimFit Filter and Insulated Frame
1" Filter replacement (Qty 12)
Internal venting kit
Masonry Chimney Vent Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
Propane Conversion Kit with Stainless Steel
Burners
Propane Conversion Kit with Stainless Steel
Burners
U fitting for gas piping
Installer's Guide
Up ow/Down ow/Horizontal
Gas-Fired, 1–Stage and 2–Stage Induced Draft Furnaces with
High Ef ciency Motor
U U p p f f l l o o w w , , D D o o w w n n f f l l o o w w , , H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t / / L L e e f f t t
Single Stage
Two Stage
S8X1A026M2PSAB
S8X2A040M3PSAB
S8X1A040M3PSAB
S8X2B060M3PSAB
S8X1B040M2PSAB
S8X2B060M4PSAB
S8X1B060M3PSAB
S8X2B080M4PSAB
S8X1B060M4PSAB
S8X2C080M5PSAB
S8X1B080M4PSAB
S8X2C100M5PSAB
S8X1C080M5PSAB
S8X2D120M5PSAB
S8X1C100M5PSAB
S8X2
S8X1D120M5PSAB
S8X1
N N o o t t e e : : This installer's Guide is used for multiple furnace families. Models
may have a "T" in the 12th digit designating they meet California less
than 40 ng/J (NOx) emissions requirements.
N N o o t t e e : : Graphics in this document are for
representation only. Actual model may
differ in appearance.
18-CE04D1-1D-EN
S S A A F F E E T T Y Y W W A A R R N N I I N N G G
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person
could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that
are attached to the equipment.
1 1 8 8 - - C C E E 0 0 4 4 D D 1 1 - - 1 1 D D - - E E N N
May 2020
Use with
All Furnaces
B Cabinet Furnaces
C Cabinet Furnaces
D Cabinet Furnaces
All Furnaces in Downflow orientation
All Furnaces
All furnaces when used in side return
application
B Cabinet furnaces only when in bottom return
application
BAYSF1255BA
B, C, and D Furnaces in Downflow orientation
All furnaces
S8X1A026M2P*
S8X1A040M3P*, S8X1B040M2P*
S8X2A040M3P*
S8X1C080M5P*, S8X1C100M5P*,
S8X1D120M5P*
S8X1B060M3P*, S8X1B060M4P*,
S8X1B080M4P*
S8X2C080M5P*
S8X2B060M3PSAAA, S8X2B060M4PSAAA
S8X2B080M4P*
S8X2C100M5P*
S8X2B060M3PSAAB & later,
S8X2B060M3PTAAA & later,
S8X2B060M4PSAAB & later,
S8X2B060M4PTAAA & later
S8X2D120M5P*
All Furnaces except S8X1A026
S8X1A026 Furnace only
All Furnaces for right hand gas entry
18-CE04D1-1D-EN

Advertisement

Table of Contents
loading

Table of Contents