Accessories

Table 1. Accessories
Model Number
BAYHANG
BAYLIFTB
BAYLIFTC
BAYLIFTD
BAYBASE205
BAYFLTR203
BAYFLTR204
BAYFLTR205
BAYFLTR206
BAYSF1165*
(a)
BAYSF1255*
BAYVENT600A
BAYVENT800B
BAYSWT21AHALTA
BAYSWT15AHALTA
BAYSWT14AHALTA
BAYLPSS400*
FLRSF1255
PIP02095
(a)
Airflow greater than 1600 CFM requires dual returns

Document Pack Contents

Item
Qty.
Description
1
1
Plug — Gas
2
1
Installation, Operation, and
Maintenance
3
1
Owner Guide
4
1
Limited Warranty
5
2
Tinnerman Clips (not pictured)
Note: Tinnerman Clips should be
kept with unit and are used
if the door panel flange hole
(s) becomes stripped.
6
2
Brand Labels

Parts List

Igniter
Flame Sensor
In-shot Burner(s)
Gas Valve
8
Description
Horizontal Hanging Kit
Dual Return Kit (B size extension)
Dual Return Kit (C size extension)
Dual Return Kit (D size extension)
Downflow Subbase
Horizontal Filter Kit
Horizontal Filter Kit
Horizontal Filter Kit
Filter Access Door Kit (Downflow only)
1" SlimFit Box with MERV 4 Filter
2" SlimFit Filter Box with MERV 4 Filter
Internal venting kit
Masonry Chimney Vent Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
High Altitude Pressure Switch Kit
Propane Conversion Kit with Stainless Steel
Burners
1" Filter replacement (Qty 12)
U fitting for gas piping
Installation, Operation, and Maintenance
Upflow/Downflow/Horizontal Left/Right
Gas-Fired, Single Stage Induced Draft Furnaces with High
Efficiency Motor
Upflow, Downflow, Horizontal Right/Left
Single Stage
A801X040AM3SD
A801X040BM2SD
A801X060BM4SD
A801X080BM4SD
A801X080CM5SD
A801X100CM5SD
A801X120DM5SD
This Installation, Operation, and Maintenance is used for
Graphics in this document are for
multiple furnace families. Models may have a "T" in the 12th.
igit designating they meet California less than 40 ng/J
.
(NOx) emissions requirements.
WARNING
FIRE HAZARD!
Failure to follow this Warning could result in property damage, severe personal
injury, or death.
This Warning applies to installations with a ammable refrigeration system.
The furnace must be powered except for service. The furnace shall be installed
and connected according to installation instructions and wiring diagrams that
are provided with the evaporator coil.
SAFETY WARNING
Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment
can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death or
serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment.
July 2023
A801X-SVX001-1B-EN
Inducer Assembly
Blower Motor
Blower Wheel
IFC (Integrated Furnace Control)
Use with
All Furnaces
B Cabinet Furnaces
C Cabinet Furnaces
D Cabinet Furnaces
All Furnaces in Downflow orientation
B Cabinet Modular Blowers in Downflow/
Horizontal
C Cabinet Modular Blowers in Downflow/
Horizontal
D Cabinet Modular Blowers in Downflow/
Horizontal
All Furnaces in Downflow orientation
All Furnaces
All furnaces when used in side return
application
B-Cabinet Furnaces only when in bottom return
application
B, C, and D Furnaces in Downflow orientation
All furnaces
A801X040AM3*, A801X040BM2*
A801X060BM4*, A801X080BM4*
A801X080CM5*, A801X100CM5*,
A801X120DM5*
All Furnaces except A801X026
BAYSF1255*
All Furnaces for right hand gas entry
representation only. Actual model may differ
in appearance.
A801X-SVX001-1B-EN
Pressure Switch(es)
Main Thermal Limit
Roll-Out Switch(es)
Reverse Air Switch(es)