INSTALLATION
Adapt the hob to a particular
type of gas
This may be performed by an installer with the
appropriate qualifications only.
If the gas, which the hob will be supplied with
is different from the gas type specified by the
manufacturer, i.e. G20 (2H) 20 mbar, replace
the burner nozzles and adjust the flame.
CAUTION!
Hobs supplied by the manufacturer are fitted
with burners designed for the gas specified on
the nameplate and in the warranty.
Nameplate is located on the bottom of the
housing and lists information on the type of
gas the appliance is intended for.
In order to adapt the hob to another gas type:
• replace the nozzles (see table),
• adjust the valves for a reduced flow.