The cross-section of the chimney must be at least that of the
flue pipe. Ø 150 mm/177 cm 2 cross section.
Several solid fuel products can be connected to the same
chimney system if the chimney cross-section is adequate.
Contact your local building authorities regarding restrictions
and installation requirements.
The chimney must be connected in accordance with the
installation instructions of the chimney supplier.
Make sure that the flue pipe rises all the way up to the
chimney.
Please note that it is extremely important for connections to
have a degree of flexibility.
The recommended chimney draught is 16-18 Pa.

4.0 Installation

NB: Before installing the fireplace, check it carefully for any signs
of damage.
NB: The product is heavy! Ask someone to help you when
positioning and installing it.
NB: Read the Installation and Operating Instructions for the
Jøtul I 520 (Cat. no. 10046368) and Jøtul FS 73 (Cat. no. 10046753)
carefully before installing the fireplace!
Use the acrylic sealant provided for all joints.
4.1 Prior to installation
The basic product comes in two packages:
1. Burn chamber.
2. Concrete units with mounting sections.
NB: Check the product for signs of damage when you unpack it.
Preparations
Before installation, it is necessary to decide:
Where the smoke outlet is to be located.
Possible use and location of external air supply.
Refer to manuals for installation of the parts.
Smoke outlet
Before starting installation work, decide whether a rear or top
outlet will be used. The product is delivered from the factory with
the smoke bell positioned for a top outlet. Read the Installation
and Operating Instructions for the Jøtul I 520 (cat. no. 10046368).
Preparation before installation
Fig. 3
1. For a top outlet: Make holes for outside air connection.
For a rear outlet: Make holes for outside air connection and rear
outlet. Distance from floor to centre smoke outlet is 1225 mm.
Fig. 4
2. Fit the fireproof boards and make sure that the knockouts are
centred in relation to the outside air connection and smoke
outlet (rear outlet).
ENGLISH
Rear
smoke outlet
39