Standard Chassis Installation - Fujitsu HX2560 M1 User Manual

Table of Contents

Advertisement

HX2560 M1/HX2560 M2

Standard Chassis Installation

Installing the Chassis into a Rack
1. Confirm that the inner rails are properly installed on the chassis.
2. Confirm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure even
on both sides, until the locking tab of the inner rail clicks into the front of the
middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis all
the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles to the
front of the rack.
Ball-Bearing
Shuttle
User's Manual
Figure 2-5. Installing the Chassis into a Rack
1
7
2-8