Description of the device
4.9 Configuration License PLUG
The device has a button with the following functions:
• Reset the device to default settings
Please note that the button function distinguishes between the startup phase and running
operation.
For more information, refer to "Resetting the device to default settings with the button (in the
startup phase) (Page 81)" and "Resetting the device to default settings with the button
(during operation) (Page 82)".
• Load a firmware file via TFTP
For more information, refer to "Load a firmware file via TFTP. (Page 83)".

• Setting the display mode

The display mode is used for diagnostics of the device. Depending on the set display mode,
the LEDs of the device show different information and indicate the state of the device.
For more information, refer to "Setting the display mode (Page 40)".
For more information on the display modes, refer to "LEDs "DM1" and "DM2" (Page 39)".
4.8.2
Setting the display mode
To set the display mode, press the button as follows:
Pressing the button
starting at display mode A
-
Press once
Press twice
Press three times
Depending on the set display mode, the "L1", "L2" LEDs and the port LEDs show different
information.
If you do not press the button for longer than 1 minute, the device automatically changes to
display mode A.
4.9

Configuration License PLUG

The Configuration and License PLUG (CLP) is a USB storage medium for backing up and
exchanging data and licenses.
The CLP has a USB type C interface and can be used with the following devices that have a
corresponding interface:
• Siemens products
• Personal computers (PCs), such as desktop PCs, tablet PCs, laptops, or smartphones
40
LED status
DM1
DM2
Off
On
Off
Off
On
On
Operating Instructions, 03/2023, C79000-G8976-C586-02
Display mode
Display mode A
Display mode B
Display mode C
Display mode D