100 To 240 Vac / 110 To 250 Vdc Device Version - Siemens SIMATIC NET SCALANCE XR-300 Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Technical specifications
9.1 SCALANCE XR326-8 and SCALANCE XR326-8EEC
Technical specifications
Conformal coating of the PCBs
Design of the mounting bracket for four-point mounting
Dimensions (W x H x D)
Plate thickness
Bending radii
Surface of the housing
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Wiring rules
1)
Note the wiring rules (Page 59).
Ambient temperature with SFP
2)
The maximum ambient temperature during operation depends on the operating elevation
and the installed plug-in transceivers, see also the section "SFP plug-in transceiver (Page 31)"
in the "Accessories" section.
Restriction when operating with plug-in transceivers of this type
3)
A maximum of two plug-in transceivers of this type may be used.
Derating
4)
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
Degree of protection
5)
The degree of protection was not examined in the context of UL certification.
Degree of protection
6)
The degree of protection was not examined in the context of FM certification.
9.1.2
100 to 240 VAC / 110 to 250 VDC device version
The following technical specifications apply to the 100 to 240 V AC / 110 to 250 V DC device
version of the SCALANCE XR326-8.
Technical specifications
Connection to Industrial Ethernet
Electrical connectors
88
SCALANCE XR326-8
SCALANCE XR326-8 EEC
43.6 x 43.6 x 18.3 mm (1 height unit)
1.5 mm
1.5 mm
Stainless steel X6CR17
> 12.6 years
Quantity
Connector
Transmission speed
Properties
No
Yes
24
RJ45 jack
10 / 100 / 1000 Mbps
Half/full duplex, MDI‑X pinning
Operating Instructions, 03/2023, C79000-G8976-C586-02
 
 
2
RJ45 jack
1 / 2.5 / 5 / 10 Gbps
SCALANCE XR-300

Advertisement

Table of Contents
loading

Table of Contents