Technical specifications
Current consumption
Effective power loss
Cable cross-section
Permitted ambient conditions
Ambient temperature
2)
Relative humidity
Housing, dimensions and weight
Design
Housing material
Degree of protection
SCALANCE XR-300
Operating Instructions, 03/2023, C79000-G8976-C586-02
Rated voltage
Rated voltage
Minimum
Maximum
Property
With LAN operation with RJ45 plug
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types:
•
[-] Standard version
•
LD except SFP993-1LD
•
SFP993-1LD up to max. 4 units
Up to 2000 m above sea level
When operating with SFP Transceiv‐
ers of the type:
•
SFP993-1LD as of 5 units
Up to 2000 m above sea level
When operating with plug-in trans‐
ceivers of the types
:
3)
•
SFP992-1+
•
LD+
•
LH
•
LH+
•
ELH
•
ELH200
•
BXMR
•
BXMT
•
BX10T
•
BX10R
Up to 2000 m above sea level
With operation between 2000 m
and 3000 m above sea level
With operation between 3000 m
and 4000 m above sea level
During storage
During transportation
During operation at 25 ℃
Rack
Metal
IP20
5) 6)
9.2 SCALANCE XR322-12
3 A
72 W
0.75 mm^2 (AWG 18)
2.5 mm^2 (AWG 12)
Startup at -40 °C
During operation in horizontal installation position:
-40 to +70 °C
During operation in horizontal installation position:
-40 °C to +60 °C
During operation in horizontal installation position:
-40 °C to +55 °C
During operation in horizontal installation position:
-40 to +50 °C
The maximum ambient temperature is reduced by
5 °C
4)
The maximum ambient temperature is reduced by
10 °C
4)
-40 °C to +85 °C
-40 °C to +85 °C
≤ 95% without condensation
Technical specifications
93