Error
Code
Description
1701-xx
Hard drive format test failed.
1702-xx
Hard drive read test failed.
1703-xx
Hard drive write/read/compare test failed.
1704-xx
Hard drive random seek test failed.
1705-xx
Hard drive controller test failed.
1708-xx
Hard drive format bad track test failed.
1710-xx
Hard drive park head test failed.
1715-xx
Hard drive head select test failed.
1716-xx
Hard drive conditional format test failed.
1717-xx
Hard drive ECC* test failed.
1719-xx
Hard drive power mode test failed.
1724-xx
Hard drive network preparation test failed.
1736-xx
Hard drive monitoring test failed.
*Error Correction Code.
Error
Code
Description
1900-xx
Tape drive ID test failed.
1901-xx
Tape drive servo test failed.
1902-xx
Tape drive format or format verification test
failed.
1903-xx
Tape drive sensor test failed.
1904-xx
Tape drive BOT/EOT test failed.
1905-xx
Tape drive read test failed.
1906-xx
Tape drive write/read/compare failed.
1910-xx
Tape erase test failed.
Table E-9
Hard Drive Test Error Codes
Recommended Action
The following steps apply to error codes 1701-xx through 1736-xx:
1. Run Computer Setup and verify drive type.
2. Replace the hard drive signal and power cables and retest.
3. Replace the hard drive and retest.
4. Replace the system board and retest.
Table E-10
Tape Drive Test Error Codes
Recommended Action
The following steps apply to error codes 1900-xx through 1910-xx:
1. Replace the tape cartridge and retest.
2. Check and/or replace the signal cable and retest.
3. Check the switch settings on the adapter board (if applicable).
4. Replace the tape adapter board (if applicable) and retest.
5. Replace the tape drive and retest.
6. Replace the system board and retest.