8 OTHER FUNCTIONS

8.10 Confirming the R2 switch states and software version

R2 buffer memory
address
Station No. setting
1A0
R 2
H
switch
Data link transmission
1A1
R 2
H
speed setting switch
1A2
Mode setting switch
R 2
H
RS-232-C
1A3
R 2
H
transmission speed
RS-232-C data bit
1A4
R 2
H
length
RS-232-C parity bit
1A5
R 2
H
validity
RS-232-C stop bit
1A6
R 2
H
length
Software version
1BF
R 2
H
storage
By reading the R2 buffer memory shown below, the R2 switch state and software
version can be confirmed.
This is effective for confirming the state when the R2 switch settings are correct but the
operation is incorrect.
When using the buffer memory automatic update function to read, refer to section 5.6.
Refer to section 5.7.3 when using the transmission/reception buffer.
Name
The state of the R2 station No. setting switch is stored.
1 to 64 : Station No.
The state of the R2 data link transmission speed setting switch is stored.
(Unit: kbps)
156, 625, 2500, 5000, 10000 : Set data link transmission speed
The state of the R2 mode setting switch is stored.
0
H
1
H
2
to C
H
D
H
E
, F
H
The transmission speed set in the R2 is stored. (Unit: bps)
300, 600, 1200, 2400, 4800, 9600, 19200 : Set RS-232-C transmission
The data bit length set in the R2 is stored.
7 : 7 bits
8 : 8 bits
The validity of the parity bit set in the R2 is stored.
0 : No parity bit
1 : Odd parity bit
2 : Even parity bit
The stop bit length set in the R2 is stored.
1 : 1 bit
2 : 2 bits
The R2 software version is stored as an ASCII code.
41
H
: On-line mode (using transmission/reception buffer)
: On-line mode (using buffer memory automatic update function)
: Not used or Use not possible
H
: Hardware test mode
: Not used
H
(A) to 5A
(Z) : R2 software version
H
8 - 24
MELSEC-A
Details
speed