6. Press [+]/[-] to display transducer list. The illustration below shows the available 50
kHz transducers.
7. Select transducer type with [ ]/[ ] and then press the [MENU] key. The values for
output power, supply voltage and impedance are automatically set.
8. For 2nd transducer, select appropriate transducer as above.
9. Press the [MENU] key to close the menu and return to the SYSTEM menu.
Manual selection of transducer
If the transducer to be used is not shown on the transducer list, manually set transducer
type as below.
Note 1: When transducer 50/200-1T or 50/200-12M is used, set 50 kHz to 50B-6/6B; 200
kHz to 200B-5S. This is necessary until 50/200-1T and 50/200-12M are added to system
program.
Note 2: Max. output on transducers 50F-38 and 28F-38 is 3 kW.
1. Select TRANSDUCER SETTING from the SYSTEM menu and press the [MENU] key.
(Refer to page 3-1 for how to display the SYSTEM menu.)
2. Select MANUAL to display the following menu.
XDR SELECT
:
LO-FREQ
FREQUENCY
:
SUPPLY VOLTAGE :
IMPEDANCE
:
[50 kHz]
1kW :
50B-6/6B
50B-9/9B
50F-8G
50/200-1ST
50/200-1T
2kW :
50B-12
50/200/400
50BL_12HR
3kW :
50F-24H
50/3K/3F
50BL-24HR
[ / ]
: Select transducer.
[MENU] : Save & Exit.
Figure 3-3 Transducer selection screen (50 kHz)
TYPE
MANUAL
HI-FREQ
50 kHz
200 kHz
46 V
75 V
320Ω
100Ω
Figure 3-4 Manual Transducer selection screen
Do not manually set transducer type if
type used is programmed in this unit.
Wrong transducer setting may damage the
transducer and void the warranty.
14
CAUTION