Furuno FCV-1500 Installation Manual page 20

Color video sounder/monitor
Table of Contents

Advertisement

Thru-hull mount water temperature sensor T-02MSB, T-03MSB
When selecting a mounting location for the sensor keep in mind the following points:
• Select a mid-boat flat position.
• The sensor does not have to be installed perfectly perpendicular, however it must not
be located where it won't be damaged when the boat is dry docked.
• Select a place apart from equipment generating heat.
• Select a place in the forward direction viewing from the drain hole, to allow for circula-
tion of cooling water.
• Select a place free from vibration.
T-02MSB
Sensor
Cable
1. Drill a hole of φ21 mm in the hull.
2. Pass the sensor cable through the hull.
3. Pass the rubber gasket, washer and lock
nut onto the cable in that order.
4. Apply high-grade sealant to the sensor
flange, sensor and lock nut. Tighten the
lock nut. Do not overtighten it; torque
should be less than 59N•m.
5. Launch the boat and check for water
leakage around the sensor.
Figure 1-3 How to mount thru-hull mount water temperature sensors T-02MSB, T-03MSB
Lock Nut
Washer
Rubber Gasket
φ21 mm
Apply sealant.
T-03MSB
Lock Nut
Washer
Rubber Gasket
φ25 mm
Apply sealant.
Holder Guide
1. Drill a hole of φ25 mm in the hull.
2. Coat the holder guide with sealant, and then
pass it through the hull from outside the boat.
3. Pass the rubber gasket, washer and lock nut
onto the holder guide in that order. Tighten the
lock nut. Torque should be less than 59N•m.
4. Lead in the sensor holder from inside the boat
and set it to the holder guide. Tighten the lock
nut.
5. Launch the boat and check for water leakage
around the sensor.
3
Sensor Holder
Lock Nut
Thickness within
25 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcv-1500m

Table of Contents