Download Print this page

Omron D4DH Quick Start Manual page 9

Safety-door hinge switch

Advertisement

D4DH
Mounting Holes
Standard Model
--0.05
4
dia., height: 4.8 max.
--0.15
2-Conduit Model
--0.05
4
dia., height: 4.8 max.
--0.15
Mounting hole
Mounting surface
Insertion hole for protruding portion
--0.05
4
dia.
--0.15
Depth: 4.8 mm
Mount the shaft or arm lever with a one-way screw, or an
equivalent securely so that the shaft or arm lever cannot be
easily dismounted.
Although the shaft withstands a force exceeding 500 N, do not
impose a force of 50 N or more on the shaft.
Be sure that the arm lever moves smoothly when the door opens
or closes.
1 to 3
1 to 3
4.5 to 5 dia.
8 to 10 dia.
Arm Lever Mounting Position
The arm lever is mounted upwards in the center position before
shipping. To change the position, loosen the arm lever mounting
screw, dismount the arm lever, and mount the arm lever in the left
or right position.
Head Direction
By removing the four screws of the head, the mounting direction
of the head can be changed. The head can be mounted in four
directions. Be sure that no foreign material will enter during a
change in direction.
Wiring
Do not connect lead wires directly to the terminals. Be sure to
connect the lead wires through insulation tubes and crimp
terminals. The tightening torque applied to each crimp terminal is
0.59 to 0.78 N S m. The lead wires must be an AWG20 to AWG14
2
type (i.e., 0.5 to 2.5 mm
thick).
dz dia.:
3.7
D dia.:
4.5
B:
7.0
L:
20.2
F:
7.7
D dia.
I:
9.0 (mm)
Wire the crimp terminal as shown in the following diagram so that
it will not come in contact with the case or cover.
Correct
Terminal screw
Crimp terminal
10
dz dia.
Incorrect

Advertisement