Installation Procedure; Step 1 Choosing The Installation Location - Samsung AC BXAP G Series Installation Manual

Table of Contents

Advertisement

Installation Procedure

Step 1 Choosing the installation
location
WARNING
Because your air conditioner contains R-32 refrigerant,
make sure that it is installed, operated, and stored it
in a room whose floor area is larger than the minimum
required floor area specified in the following table:
Minimum required room area (A, m²)
Ceiling-
m (kg)
mounted type
1.843
3.64
1.9
3.75
2.0
3.95
2.2
4.34
2.4
4.74
2.6
5.13
2.8
5.53
3.0
5.92
3.2
6.48
3.4
7.32
3.6
8.20
3.8
9.14
4.0
10.1
4.2
11.2
4.4
12.3
4.6
13.4
4.8
14.6
5.0
15.8
5.2
17.1
5.4
18.6
5.6
20.0
5.8
21.5
6.0
23.0
m : Total refrigerant charge in the system
A : Minimum required room area
IMPORTANT: it's mandatory to consider either the table
1 or taking into consideration the local law regarding
the minimum living space of the premises.
Minimum installation height of indoor unit is 0.6 m for
floor mounted, 1.8 m for wall, 2.2 m for ceiling.
Wall-mounted
Floor-standing
type
type
No requirement
4.45
28.9
4.58
30.7
4.83
34.0
5.31
41.2
5.79
49.0
6.39
57.5
7.41
66.7
8.51
76.6
9.68
87.2
10.9
98.4
12.3
110
13.7
123
15.1
136
16.7
150
18.3
165
20.0
180
21.8
196
23.6
213
25.6
230
27.6
248
29.7
267
31.8
286
34.0
306
Installation location requirements
Do not place the outdoor unit on its side or upside
down. Failing to do so may cause the compressor
lubrication oil to run into the cooling circuit and lead to
a serious damage to the unit.
Install the unit in a well-ventilated location away from
direct sunlight or strong winds.
Install the unit in a location that would not obstruct any
passageways or thoroughfares.
Install the unit in a location that would not
inconvenience or disturb your neighbors, as they could
be affected by the noise or the airflow coming from
the unit.
Install the unit in a location where the pipes and the
cables can be easily connected to the indoor unit.
Install the unit on a flat, stable surface that can
withstand the weight of the unit. Otherwise, the unit
can generate noise and vibration during operation.
Install the unit so that the air flow is directed towards
the open area.
Maintain sufficient clearance around the outdoor unit,
especially from a radio, computer, stereo system, etc.
Indoor Unit
Control
Stereo Computer etc
Air Guide Duct (This product is not provided by Samsung)
Install the unit at a height where its base can be firmly
fixed in place.
Make sure that the water dripping from the drain hose
runs away correctly and safely.
Fuse
1.5 m or more
1.5 m or more
300 mm
Outdoor Unit
200 mm
English