Recorder Hardware Installation

Voice card installation and wiring

Different cabling and wiring setups are required for voice cards compatible
with the TDM Recorder. The following sections show compatible Ai-Logix
voice cards, their installation, and typical wiring requirements for digital
trunk-side (DP models), digital station-side (NGX models), and analog
station-side (LD models).
Before setting up the wiring, a site survey must be conducted to clarify cable
requirements and equipment location. Additionally, computers must be
checked to ensure that they can accommodate full length PCI cards.
Note: A Customer Supplied Unit (CSU/DSU) may be required between the
PBX and the card.
Installing the voice card
1 Ensure that the voice card is a compatible Ai-Logix model according to
the following
Ai-Logix Voice cards compatible with the TDM Recorder
Type
Analog
Station
Side
Digital
Station
Side
20
Ai-Logix
Description
Model
LD2409
Newer versions of Ai-Logix's analog station-side
recording voice cards capable of recording 4, 8, 16
and 24 ports respectively.
NGX1600 Voice card that records 16x2-wire digital stations
(8x4-wire). It is triggered by D-channel events. Can
have up to one MX80 daugtherboards attached
NGX2400 Voice card that records 24x2-wire digital stations
(12x4-wire) triggered by D-channel events.