Carrier 38MGRBQ18B-3 Service Manual page 45

Multi-zone outdoor unit ductless system sizes 18r, 24hh, 30hh, 36r, 36hh, 48r and 48hh
Table of Contents

Advertisement

38MGRBQ: Service Manual
DIAGNOSIS AND SOLUTION (CONT)
E0/ EC 51 (Outdoor unit EEPROM parameter error) diagnosis and solution
ERROR CODE
MALFUNCTION DECISION
CONDITIONS
SUPPOSED CAUSES
Troubleshooting
EEPROM: a type of memory. The contents can be erased and reprogrammed using a pulsed voltage (see figure 39).
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
E0/ EC 51
PCB main chip does not receive feedback from EEPROM chip
Installation mistake
Faulty PCB
Outdoor EEPROM malfunction
Power off, then restart the
unit 3 minutes later
Replace the outdoor main PCB
Fig. 39 — EEPROM