Quick-Start Guide for Remote Access Concentrators
118352-A Rev. A
8
3.
Save the changes you made to the RAC:
a) For the 5399 RAC, exit the ROM monitor by entering
Ctrl T. This brings you back to the System 5000 Slot
Selection Menu.
b) Enter s to select the supervisory Module main menu.
c) Enter m to select Module Information Menu.
d) At the Enter slot # (1-14): prompt enter the slot number
and press Return. Then type d to set all the changes you
made as the default.
Enable the allow_snmp_sets Parameter
If you plan to use Annex Manager or Quick2Config to configure and
manage the RAC, you must enable the allow_snmp_sets parameter. To
enable this parameter:
1.
At the console monitor prompt, enter allow_snmp_sets.
2.
Enter Y when you are asked if you want to enable this
parameter.

Task 8: Boot the RAC

Issue the boot command to boot the RAC. After the RAC boots, choose
which tools you want to use to complete the remaining configuration
tasks. The remaining tasks in this book use admin commands from the
console monitor, but you can also use na, Annex Manager, or
Quick2Config.