Table 8
Port status and Port Speed LED patterns during normal operation (continued)
LED name,
LED color
Location
Slow-flashing amber
(on 1 second, off 1
second)
Fast-flashing amber (on
1/4 second, off 1/4
second)
Alternating green and
amber
Port Speed
No light
lower LED to the
right of port
Steady green
Steady amber
42
Managing the 4Gb SAN Switch
Status of hardware
Port is disabled as a result
of diagnostics or
portDisable
command.
If the LEDs for all ports are
slow-flashing amber, the
switch could be disabled.
Port is faulty.
Port is bypassed.
Port is
transmitting/receiving at
1 Gb/sec.
Port is
transmitting/receiving at
2 Gb/sec.
Port is
transmitting/receiving at
4 Gb/sec
Recommended action
Enable the port using the
portEnable command; refer to
HP StorageWorks Fabric OS 5.0
command reference guide for
more information. If the LEDs for all
ports are slow-flashing amber,
enable the switch by entering the
switchEnable command.
Check the Port Status LEDs, error
log, transceiver, and cable or
loopback plug.
Clear the error log.
Rerun the diagnostics to verify that
the error condition is fixed.
Check configuration of FC loop.
No action required.
No action required.
No action required.