H9: Relay Card Parameters; Relay Card Output Configuration - Bosch rexroth EFC 610 Series Operating Instructions Manual

Frequency converter
Hide thumbs Also See for rexroth EFC 610 Series:
Table of Contents

Advertisement

460/653
Functions and Parameters

12.23 H9: Relay Card Parameters

12.23.1 Relay Card Output Configuration

This function defines the 4 relays output in relay extension card for system state
monitoring.
Code
Name
Extended relay 1 output
H9.00
selection
Extended relay 2 output
H9.01
selection
Extended relay 3 output
H9.02
selection
Extended relay 4 output
H9.03
selection
Relay output setting val-
H9.10
ue
Relay card output chan-
H9.97
nel diagnosis
Setting range of H9.00...H9.03:
0: Converter ready
Bosch Rexroth AG R912005854_Edition 09
Rexroth Frequency Converter EFC x610
Setting range
0...25
Relay1 is defined by
bit0, when bit0 is '0',
R1b_R1a is opened;
when bit0 is '1',
R1b_R1a is closed
Relay2 is defined by
bit1, when bit1 is '0',
R2b_R2a is opened;
when bit1 is '1',
R2b_R2a is closed
Relay3 is defined by
bit2, when bit2 is '0',
R3b_R3a is opened;
when bit2 is '1',
R3b_R3a is closed
Relay4 is defined by
bit3, when bit3 is '0',
R4b_R4a is opened;
when bit3 is '1',
R4b_R4a is closed
0: Inactive
1: Relay1 diagnosis
2: Relay2 diagnosis
3: Relay3 diagnosis
4: Relay4 diagnosis
5: All output diagnosis
Default
Unit
Step
0
0
0
0
0
0
Series
Attri.
Stop
Stop
Stop
Stop
Run
Stop