Digital Setting Frequency - Bosch rexroth EFC 610 Series Operating Instructions Manual

Frequency converter
Hide thumbs Also See for rexroth EFC 610 Series:
Table of Contents

Advertisement

Rexroth Frequency Converter EFC x610
Series

12.8.3 Digital Setting Frequency

This function defines the digital setting frequency and four different saving
modes during fine tuning of the setting frequency by using <▲> / <▼> or digital
inputs, so that unexpected data loss in commissioning or actual application en-
gineering process can be avoided.
Code
Name
Digital setting frequency
E0.06
saving mode
E0.07 Digital setting frequency
When parameter E0.00 'First frequency setting source' or E0.02 'Second fre-
quency setting source' is set to 1 'Panel button setting', the setting frequency is
set by parameter E0.07 'Digital setting frequency'. Pressing <▲> and <▼> buttons
on the operating panel will decrease and increase the output frequency respec-
tively when the frequency converter is running.
During fine tuning of the setting frequency by using <▲> / <▼> or digital inputs in
the actual application engineering process, E0.06 'Digital setting frequency sav-
ing mode' defines the following saving modes:
0: Not saved when powered off or stopped
1: Not saved when powered off; saved when stopped
2: Saved when powered off; not saved when stopped
3: Saved when powered off or stopped
4: Not saved when powered off; memorized when stopped
Setting range
Default
0...4
0.00...[E0.09] Hz
50.00
R912005854_Edition 09 Bosch Rexroth AG
Functions and Parameters
Unit
Step
0
-
-
Hz
0.01
203/653
Attri.
Stop
Run

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth efc 3610Rexroth efc 5610

Table of Contents