4-4. Checking After Adjustment

To check the values after adjustment, turn off the camera
once, then remove the commander and the commander
relay tool from the camera. Then turn it on again before
checking.

4-4-1. Checking INT VCXO Adjustment

1. Set a DIP switch on highest of the rear panel of the
camera to INT position. (SSC-DC314/DC318P)
2. Slide the sliding switch (S301) on the camera MB
board to connector side (CN301).
3. Confirm that the INT VCXO (CN301, pin-10) frequency
is within the specification.
4. After the checking, slide the sliding switch (S301) on
the camera MB board to IC side (IC305).
S301
- MB-925 Board (B side) -
Subject
: Unnecessary
Measurement point : CN301, pin-10
INT VCXO/MB board
Equipment
: Frequency counter
: 14318181.5 ± 25.0 Hz (SSC-DC314)
Specification
14187400 ± 25 Hz
(SSC-DC310P/DC318P)

4-4-2. Checking SYNC Level Adjustment

Check to see if the measured voltage is within the specifi-
cation range.
Subject
: Unnecessary
Measurement point : SYNC level of VIDEO OUT
Equipment
: Waveform monitor
: 40 ± 4 IRE (SSC-DC314)
Specification
300 ± 30 mV (SSC-DC310P/DC318P)
Lens iris
: Close
4-10
IC305
CN301

4-4-3. Checking Burst Level Adjustment

Check to see if the measured voltage is within the specifi-
cation.
Subject
: Unnecessary
Equipment
: Vectorscope
Specification
: Burst level is 75%

4-4-4. Checking SET UP Adjustment

Check to see if the measured voltage is within the specifi-
cation.
Subject
: Unnecessary
Measurement point : SET UP level of VIDEO OUT
Equipment
: Waveform monitor
: 5 ± 2 IRE (SSC-DC314)
Specification
20 ± 15 mV (SSC-DC310P/DC318P)
Lens iris
: Close

4-4-5. Checking White Clip Level Adjustment

1. Turn OFF the CCD-IRIS switch on the rear panel of
the camera.
2. Shooting the all white pattern, then fully open the lens
iris.
3. Confirm that the white clip level of VIDEO OUT is
within the specification.
Subject
: All white pattern
Measurement point : White clip level of VIDEO OUT
Equipment
: Waveform monitor
: 110 ± 5 IRE (SSC-DC314)
Specification
786 ± 40 mV (SSC-DC310P/DC318P)
Lens iris
: Open