4-3-5. SET UP Adjustment

1. Press the STEP FORWARD button of the commander
once.
As a result, the displayed mode will change to "D9".
2. Press the CHANGE DATA button to ensure that the
measured voltage is within the specification.
Subject
: Unnecessary
Measurement point : SET UP level of VIDEO OUT
Equipment
: Waveform monitor
Display Mode
: D9
: 5 ± 2 IRE (SSC-DC314)
Specification
15 ± 15 mV (SSC-DC310P/DC318P)
Lens iris
: Close

4-3-6. OB Level Adjustment

1. Press the STEP FORWARD button of the commander
once.
As a result, the displayed mode will change to "33".
2. Press the CHANGE DATA button to ensure that the
measured voltage is within the specification.
Subject
: Unnecessary
Measurement point : OB level of VIDEO OUT
Equipment
: Waveform monitor
Display Mode
: 33
: 7 ± 2 IRE (SSC-DC314)
Specification
20 ± 15 mV (SSC-DC310P/DC318P)
Lens iris
: Close
4-6

4-3-7. White Clip Level Adjustment

1. Press the STEP FORWARD button of the commander
once.
As a result, the displayed mode will change to "E3".
2. Shooting the all white pattern, then fully open the lens
iris.
3. Press the CHANGE DATA button to ensure that the
measured voltage is within the specification.
Subject
Measurement point : White clip level of VIDEO OUT
Equipment
Display Mode
Specification
Lens iris
SET UP Level
OB Level
: All white pattern
: Waveform monitor
: E3
: 110 ± 5 IRE (SSC-DC314)
786 ± 40 mV (SSC-DC310P/DC318P)
: Open
White clip Level
SSC-DC314/DC318P/DC310P (UC, CE)