4-1-4. Adjustmant Commander Relay Tool
Before adjustment, slide the sliding switches on the
Adjustment commander relay tool as follows.
(Refer to Section 4-2-1)
S101
: WRT/ADJ
S102
: LOW/HI
S103
: PAL/NTSC
The signals required for adjustment are available at the test
pins on the Adjustment commander relay tool.
TP1
: CCD LEVEL
TP2
: A/D IN
TP3
: V SUB
TP4
: PG
TP5
: IRIS OUT
TP6
: VCO CONT
TP7
: INT VCXO
E1
: GND
- Commander relay tool -
SSC-DC314/DC318P/DC310P (UC, CE)
E1
TP7
TP6
TP5
TP4
TP3
TP2
TP1
4-1-5. Chart to Select Items Requiring
Adjustment
Begin selection
(Note)
Is required writing
in initial data?
(Note)
No
Adjust camera
End of Adjustment
The writing in initial data
should be performed when
replacing IC309 on the MB board.
Yes
Write in initial data
(Refer to 4-2-2.)
4-3