Rated voltage, rated frequency, rated current, rated output
Rated voltage in V n
Input
Output
Rated frequency f n
Input
Output:
Rated current I n
Input
Output
DC link voltage V dn
Rated output
Auxiliary power supply
Loading Class II acc. to EN 60146-1-1
Rated current
Base load time
Overcurrent
Overcurrent time
Losses, cooling, power factor
Power factor
Supply cosϕ 1N
Converter cosϕ U
Efficiency η
Pulse frequency 3 kHz
Power loss
Pulse frequency 3 kHz
Required cooling air flow
Pressure drop ∆p
Sound pressure level, dimensions, weights
Sound pressure level
Type
Width
Height
Depth
Weight
IP00
IP20
Siemens AG
6SE7087-6AH70
SIMOVERT MASTER DRIVES
Drive converter types
6SE70...
6SE70...
32-1HH20
6SE70...
V
3 AC 660 ... 690 ±15 %
3 AC 0 ... Rated input voltage
Hz
FC
U/f = konst
U = konst
VC
U/f = konst
U = konst
SC
A
208
208
V
kVA
238...249
V
DC 24 (20-30) (3 A without Options; with Options refer to Section 6.1)
A
189
s
A
284
s
> 0,98
< 0,92 ind.
0,97
kW
6,50
m 3 /s
0,57
Pa
256
dB(A)
86
H
mm
508
1580
460
kg
220
240
Operating Instructions
50/60 ± 6 %
0 ... 300
8 ... 300
0 ... 600
8 ... 300
0 ... 400
890...930
240
60