Creating a Physical Dante Network

A physical network is required to share Dante audio channels between a DMP 128 AT device and a NetPA AT. The NetPA 502 AT
and NetPA 1001-70V AT have an RJ-45 connector located on the back panel that accepts a standard network cable.
A DMP 128-based Dante network can be configured in a star or daisy chain network topology using the four port switch and the
Dante Controller in switched mode.
Star network topology places one DMP 128 C AT as the central unit, which connects directly to up to three more units.
Alternatively, a larger network switch in place of the central DMP 128 AT, allows more than four NetPA ATs to connect in the star
configuration.
NetP
NetPA 50
NetPA 502 AT
A
502 AT
2 AT
100-240V
0.5AMAX
NetPA 502 AT
NetPA 502 AT
GAIN
LINE OUT
REMOTE
AT
8Ω/4Ω OUTPUTS
8Ω/4Ω OUTPUTS
1
2
1
2
1
1
2
2
-4
-4
-6
-2
-6
-2
-8
0
-8
0
G
LINK
RESET
RESET
-12
+2
+2
-20
+4
+4
-
+6
-
+6
CLASS 2 WIRING
CLASS 2 WIRING
50-60Hz
DMP 128 C AT
100-240V ~ --A MAX
1
2
3
4
9
10
DMP 128 C AT
MIC +48V
1
2
3
4
5
6
7
8
11
12
50/60 Hz
5
6
7
8
Star Network Topology
Figure 4.
A daisy chain configuration can also be used. Each NetPA AT device can connect only to the end of the chain.
1
2
3
4
9
10
DMP 128 C AT
100-240V ~ --A MAX
MIC +48V
1
2
3
4
5
6
7
8
11
12
50/60 Hz
5
6
7
8
Daisy Chain Topology
Figure 5.
Hybrid versions combining the star and daisy chain topologies can be built, but a ring topology, or any topology that creates a
duplicate connection causes a connection failure in Dante Controller.
NOTE:
Connections between ports in either a star or daisy chain network do not need to be sequential (1 to 2, 2 to 3, 3 to 4),
nor do they need to be made between the same port numbers (1 to 1, 2 to 2, 3 to 3, 4 to 4).
NOTE:
At the moment, Dante is not compatible with EEE (Energy Efficient Ethernet) technology. Care should be taken when
using a network switch with this technology in a Dante network.
If using a managed switch, ensure that it supports disabling EEE on all ports that will be used for Dante traffic.
If using an unmanaged switch, do not use models that support the EEE function, as it can not be disabled on these
models.
For more information on this topic, see the
Resetting the NetPA AT
The NetPA AT utilizes DHCP addressing by default.
A recessed reset button on the rear panel (see
to DHCP (Dante default), clear the previous IP address, and reset the device name to default.
NOTE:
Initiating a reset while the NetPA AT is connected to a transmitting device severs that connection.
To reset the NetPA AT, press and hold down the reset button for ten seconds until both of the rear panel RJ-45
Ethernet port LEDs blink twice.
NOTE:
When the NetPA AT is first powered on, or reset, the default name shall be "NetPA-xxxxxx" where
xxxxxx are the last six digits or letters of the MAC address of the unit.
NetPA 502 AT
NetP
NetPA 50
A
502 AT
2 AT
NetPA 502 AT
NetPA 502 AT
100-240V
0.5AMAX
GAIN
LINE OUT
NE OUT
REMOTE
REMOTE
AT
AT
8Ω/4Ω OUTPUTS
8Ω/4Ω OUTPUTS
1
2
2
1
1
2
2
1
2
-6
-4
-2
-6
-4
-2
-8
0
-8
0
G
G
LINK
LINK
RESET
RESET
-12
+2
+2
-20
+4
+4
-
-
+6
+6
CLASS 2 WIRING
CLASS 2 WIRING
50-60Hz
NetP
NetPA 502 AT
NetPA 50
A
502 AT
2 AT
100-240V
0.5AMAX
GAIN
1
-6
-4
-2
-8
0
-12
+2
-20
+4
-
+6
50-60Hz
1
2
3
4
1 2 3 4 5 G
6
7 8 9 10 G
1
2
3
4
5
6
7
8
RS-232
RESET
11 12 13 14 15 G
16 17 18 19 20 G
Tx Rx G
EXP
LAN
Star Network Topology
DMP 128 AT
AXP 50 C AT #1
1
2
3
4
1 2 3 4 5 G
6
7 8 9 10 G
POWER
1
2
3
4
12V
1.0A MAX
5
6
7
8
RS-232
RESET
11 12 13 14 15 G
16 17 18 19 20 G
Tx Rx G
EXP
LAN
Daisy Chain Network Topology
Audinate
figure 1
NetPA 502 AT
LINE OUT
REMOTE
AT
8Ω/4Ω OUTPUTS
1
2
2
1
2
-6
-4
-2
-8
0
G
LINK
RESET
+2
+4
-
+6
CLASS 2 WIRING
AXP 50 C AT #2
1
2
3
4
5
1
IN G
01 02 IN G 01 02 IN G 01 02
IN G 01 02 IN G 01 02
IN G
01 02 IN G 01 02 IN G 01 02
POWER
1
2
3
4
12V
1.0A MAX
1
2
3
4
5
1
RESET
AXP 50 C AT
website.
G
,
, on page 1) initiates a reset mode. Reset sets the IP addressing mode
Product Category
NetPA 502 AT
NetP
NetPA 50
100-240V
0.5AMAX
2
3
4
5
GAIN
1
IN G 01 02 IN G 01 02
1
2
2
3
3
4
4
-4
-6
-2
-8
0
-8
-12
+2
2
3
4
5
-20
+4
-
+6
-
RESET
RESET
AXP 50 C AT
AXP 50 C AT
50-60Hz
A
502 AT
2 AT
NetPA 502 AT
LINE OUT
REMOTE
AT
8Ω/4Ω OUTPUTS
1
2
1
2
2
-4
-6
-2
0
G
LINK
RESET
+2
+4
+6
CLASS 2 WIRING
AT
LINK
Ethernet Port LEDs
9

Advertisement

Table of Contents
loading

Table of Contents