3.5.4 Required Bandwidth per Connection

Note that the bandwidth calculation is based on 70 bytes of overhead: RTP (12
bytes), UDP (8 bytes), IP (20 bytes), 802.1Q VLAN Tagging (4 Bytes), MAC (incl.
Preamble, FCS, 26 Bytes).
IMPORTANT: Bandwidth requirements assume Full Duplex operation!
When running Half Duplex, twice the bnadwidth is required.
Bandwidth for active DMC master connections without SPE:
Codec
Sampling
Time [ms]
G.711
10
20
30
40
G.729AB
20
30
40
60
G.723
30
60
Table 3
Bandwidth for active DMC master connections without SPE
Bandwidth for active DMC master connections with SPE:
Codec
Sampling
Time [ms]
G.711
10
20
30
40
G.729AB
20
30
40
Table 4
Bandwidth for active DMC master connections with SPE
HiPath 4000 V5, IP Solutions - HG 3500 & HG 3575, Service Documentation
Payload
Payload
Frames per
[Bytes]
second
100,00
80
50,00
160
33,33
240
25,00
320
50
20
33,33
30
25,00
40
16,67
60
33.33
24
16,67
48
Payload
Payload
Frames per
[Bytes]
second
100,00
90
50
170
33,33
250
25,00
330
50
30
33,33
40
25,00
50
A31003-H3150-S104-2-7620, 03/2009
Total
Bandwidth
Bytes
[Bit/s]
150
120000
230
92000
310
82667
390
78000
90
36000
100
26667
110
22000
130
17333
94
25067
118
15733
Total
Bandwidth
Bytes
[Bit/s]
160
128000
240
96000
320
85333
400
80000
100
40000
110
29333
120
24000

Advertisement