ELECTRICAL WORK
Wired remote controller cabling
• Strip off approx. 14 mm the cable to be connected.
• Non polarity, 2 core cable is used for cabling of the remote controller.
• Twist cable of the remote controller to be connected with cable of the remote controller unit (or sensor), and
press-fit them with a wire joint.
Wire joints (White: 2 pieces) are included in the attachments to the remote controller (sold separately) or the
wireless remote control kit (sold separately).
Cabling diagram
Never touch remote controller wiring with another 200–240V wiring. (Otherwise, the system will fail.)
Wiring diagram
This wiring diagram is single combination, about twin combination see 17 page.
• For details of cabling/installation of the wired remote controller, refer to the Installation Manual attached to in the
wired remote controller.
EN
Toshiba 1074007701(01EN)_P11-22
Terminal block for
remote controller
cabling of indoor unit
A
B
Remote controller cable
Connecting part
(Local procure)
Remote controller cabling
Cable from remote
controller unit
Remote controller
Remote controller
cable
Indoor side
Indoor/Outdoor
connecting cable
Outdoor side
(Single phase 220–240V)
3
14
Approx. 200 mm
W : White
B : Black
W
Remote controller
unit or sensor part
B
Remote controller
unit or cable from
sensor part
Wire joint
A
B
1
2
3
1
2
3
L
N
13