Clearances To Combustibles; Alcove Clearances; Mobile Home Installation - Regency Greenfire GF55-2 Specification Sheet

Table of Contents

Advertisement

CLEARANCES TO COMBUSTIBLES

These dimensions are minimum clearances to combustibles, however it
is highly recommended that you leave sufficient room on each side (20"
where possible) for servicing, routine cleaning and maintenance.
This pellet stove requires floor protection. The floor protection must be
non-combustible, extending 6" (150mm) beyond the full width and depth
of the unit including 6" (150mm) in front for ember protection.
Floor Protection:
Width
36-7/16" (934mm)
Depth
36" (914mm)
Floor Protection
Back wall
6"
(152mm)
*NOTE: If the unit is installed as a corner installation,
clearances change from 2" to 3", see "Corner thru Wall
Installation" section.
Minimum Clearances to Combustibles
2
| GF55-2 Pellet Stove
Adjacent
3" (76mm)
wall
2"
(51mm)*
CLEARANCES

ALCOVE CLEARANCES

Minimum Height
48" (1219mm)
Maximum Depth

MOBILE HOME INSTALLATION

• Secure the heater to the floor using the holes in the pedestal of the
appliance.
• Ensure the unit is electrically grounded to the chassis of your home
(permanently).
WARNING: Do not install in a room people sleep in.
CAUTION: The structural integrity of the manufactured home
floor, wall and ceiling/roof must be maintained.
• Outside fresh air is mandatory. Secure outside air connections directly
to fresh air intake pipe and secure with three (3) screws evenly spaced.
Minimum Width
36" (914mm)
30" (762mm)
Alcove Clearances
Mobile Home Install Mounting