Hitachi SH1 Series Basic Manual page 91

Hide thumbs Also See for SH1 Series:
Table of Contents

Advertisement

Chapter 4
[Hd202]~[Hd237]
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Hd202
Sync. Motor capacity setting, 2nd-motor
Hd203
Sync. Motor poles setting, 2nd-motor
Hd204 Sync. Base frequency setting,
2nd-motor
Hd205 Sync. Maximum frequency setting,
2nd-motor
Hd206 Sync. Motor rated voltage,
2nd-motor
Hd208 Sync.Motor rated current,
2nd-motor
Hd210 Sync.Motor constant R, 2nd-motor Same as Hd110
Hd212 Sync.Motor constant Ld,
2nd-motor
Hd214 Sync.Motor constant Lq,
2nd-motor
Hd216 Sync.Motor constant Ke,
2nd-motor
Hd218 Sync.Motor constant J, 2nd-motor Same as Hd118
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Hd230 Minimum Frequency for Sync.M,
2nd-motor
Hd231 No-Load current for Sync.M,
2nd-motor
Hd232 Starting Method for Sync.M,
2nd-motor
Hd233 IMPE 0V wait number for
Sync.M, 2nd-motor
Hd234 IMPE detect wait number for
Sync.M, 2nd-motor
Hd235 IMPE detect number for Sync.M,
2nd-motor
Hd236 IMPE voltage gain for Sync.M,
2nd-motor
Hd237 IMPE Mg-pole position offset,
2nd-motor
Range
Initial
(unit)
value
Same as Hd102
Same as Hd103
Same as Hd104
Same as Hd105
Same as Hd106
Same as Hd108
Same as Hd112
Same as Hd114
Same as Hd116
Initial
Range (unit)
value
Same as Hd130
Same as Hd131
Same as Hd132
Same as Hd133
Same as Hd134
Same as Hd135
Same as Hd136
Same as Hd137
4-48
For parameter configuration
[oA-10]~[oA-33][ob-01]~[ob-04]
■Parameter mode (o code)
・o parameters are displayed by the [UA-22] = 01. This
configuration is not necessary except when option is used.
・For more information, refer to the User's guide of the
corresponding option.
Optional board error operation
Code/Name
oA-10
Operation
selection on option card
error (SLOT-1)
oA-11
Communication
Watch Dog Timer (SLOT-1)
oA-12
Action selection
at communication error
(SLOT-1)
oA-13
RUN command
selection at start up
(SLOT-1)
oA-20
Operation
selection on option card
error (SLOT-2)
oA-21
Communication
Watch Dog Timer (SLOT-2)
oA-22
Action selection
at communication error
(SLOT-2)
oA-23
RUN command
selection at start up
(SLOT-2)
oA-30
Operation
selection on option card
error (SLOT-3)
oA-31
Communication
Watch Dog Timer (SLOT-3)
oA-32
Action selection
at communication error
(SLOT-3)
oA-33
RUN command
selection at start up
(SLOT-3)
・For more information, refer to the User's guide.
P1-FB Optional board encoder input setting
Code/Name
ob-01
Encoder constant setting
ob-02
Encoder position selection
ob-03
Motor gear ratio
Numerator
ob-04
Motor gear ratio
Denominator
・Sets the encoder to be input into the optional board,
and sets the motor gear ratio involved in the feedback
of the encoder.
Initial
Range (unit)
00(Error)/
01(Continue operation)
0.00~100.00(s)
00(Error)/
01(Tripping after decelerating
and stopping the motor)/
02(Ignore error)/
03(Free-run stop)/
04(Decelerating and stopping)
00(Disable)/
01(Enable)
00(Error)/
01(Continue operation)
0.00~100.00(s)
00(Error)/
01(Tripping after decelerating
and stopping the motor)/
02(Ignore error)/
03(Free-run stop)/
04(Decelerating and stopping)
00(Disable)/
01(Enable)
00(Error)/
01(Continue operation)
0.00~100.00(s)
00(Error)/
01(Tripping after decelerating
and stopping the motor)/
02(Ignore error)/
03(Free-run stop)/
04(Decelerating and stopping)
00(Disable)/
01(Enable)
Initial
Range (unit)
value
0~65535(Pulse)
1024
00(A Phase, Cos lead)/
01(B Phase, Sin lead)
1~10000
1~10000
value
00
1.00
01
00
00
1.00
01
00
00
1.00
01
00
0
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents