Chapter 4
[AJ-33]~[AJ-39]
Code/Name
AJ-33
PID3 proportional gain
AJ-34
PID3 integral time constant
AJ-35
PID3 derivative gain
・Sets the PID3 gain.
・If [PIDC] terminal is active (ON), the value of the
integral constant is purged. If done while operating, the
operation can become instable/insecure.
Code/Name
AJ-36
PID3 output variable
PID output (%)
PID
Target
value
・Limits the output range of the PID. If [AJ-36]=0.00 the
limit is disabled.
Code/Name
AJ-37
PID3 deviation over
level
PID deviation (%)
0%
Output
terminal
ON
047[OD3]
・When the PID deviation pass over ±[AJ-37], the output
terminal function 089[OD3] is activated.
Code/Name
AJ-38
PID3 feedback compare
signal turn-off level
AJ-39
PID3 feedback compare
signal turn-on level
PID feedback (%)
0%
Operation
command
048[FBV3]
ON
・When the PID feedback cross over the [AJ-18] level, the
output terminal function 090[FBV3] is deactivated
(OFF). If it crosses under the [AJ-39] level, is activated
(ON).
Initial
Range (unit)
value
1.0
0.0~100.0
0.0~3600.0(s)
1.0
0.00
0.0~100.00(s)
Range (unit)
Initial value
0.00
0.00~100.00(%)
PID output range
[AJ-36]
[AJ-36
]
Time(s)
Range (unit)
Initial value
0.00~100.00(%)
3.00
[AJ-37]
[AJ-37]
ON
Time(s)
Range (unit)
Initial
value
0.00~100.00(%)
100.00
0.00~100.00(%)
0.00
[AJ-38]
[AJ-39]
Time(s)
ON
ON
For parameter configuration
PID4 function
Code/Name
AJ-41
PID4
enable
・Validates the PID4 operation.
・If [AJ-41]=01 when the PID output reaches a negative
value, the PID output is limited to 0.
・If [AJ-41]=02 when the PID output reaches a negative
value, the PID output lets out an inverted output.
・By activating the [PID4] terminal, the PID4 output
becomes 0.
Code/Name
AJ-42
PID4 deviation inverse
PID target
value
Feedback
value
・PID4 deviation can be reversed.
Code/Name
AJ-43
PID4 unit selection
AJ-44
PID4 scale adjustment (0%)
AJ-45
PID4 scale adjustment (100%)
AJ-46
PID4 scale adjsutment
(decimal point)
・You can switch the display data and the display unit
involved in the output of the PID control by the
calculation.
Code/Name
AJ-47
Input source selection
of process data for PID4
AJ-50
Set point setting for
PID4
・When PID4 target value input is selected, if the selected
is the parameter setting, [AJ-50] gets enabled.
Code/Name
AJ-52
Feedback data
reference selection for PID4
・Selects the PID4 feedback reference.
*1)00(Not used)/01(Ai1 terminal)/02(Ai2 terminal)/03(Ai3 terminal)/
04(Ai4 terminal)/05(Ai5 terminal)/06(Ai6 terminal)/07(Parameter)/
08(RS485)/ 12(Pulse train input: main)/ 13(Pulse train input:
option)/15(PID1 output)
4-23
[AJ-41]~[AJ-52]
Range (unit)
00(Disable)/01(Enable)/
02(Enable:inverted output)
Range (unit)
00(Disable)/
01(Enable)
Reverse PID4
+
[AJ-42]
-
00
01
-
+
Range (unit)
<unit table> at the end
of the document can
be consulted
-10000~10000
-10000~10000
0~4
Range (unit)
00~08, 12, 13, 15 *1)
-100.00~100.00(%)
Range (unit)
00~08, 12, 13, 15 *1)
Initial
value
00
Initial value
00
PID
operation
Initial
value
03
0
10000
2
Initial
value
07
0.00
Initial
value
02