Hitachi SH1 Series Basic Manual page 87

Hide thumbs Also See for SH1 Series:
Table of Contents

Advertisement

Chapter 4
[Hb110]~[Hb131]
Induction motor constants
Code/Name
Hb110
Async.
0.000001~1000.000000 (Ω)
Motor constant R1,
1st-motor
Hb112
Async.
0.000001~1000.000000 (Ω)
Motor constant R2,
1st-motor
Hb11
Async.
0.000001~1000.000000 (mH)
Motor constant L,
1st-motor
Hb116
Async.
0.01~1000.00 (A)
Motor constant Io,
1st-motor
Hb118
Async.
0.00001~10000.00000 (kgm2)
Motor constant J,
1st-motor
・If the motor capacity[Hb102] and number of poles
[Hb103] are changed, the motor characteristics are set
according to the internal Hitachi table values.
・For no-rotation auto-tuning, the following variables
are acquired:[Hb110]~[Hb114].
・For rotation auto-tuning, the following variables are
acquired:[Hb110]~[Hb118]
・It is possible to input the data obtained from the motor
manufacturer. However, it must also include the data of
the wiring and the like.
Minimum frequency setting
Code/Name
Hb130
Minimum frequency,
1st-motor
Hb131
Reduced voltage start
time, 1st-motor
・If the torque at the time of start-up is not enough, you
can change the settings to raise the lowest frequency.
・Raise the minimum frequency, if the trip occurs, set a
longer time of reduced voltage start selection.
FW
Minimum frequency
[Hb130]
Output
frequency
Output
Reduced voltage
voltage
00
start [Hb131]
Initial
Range (unit)
value
Motor
capacity
setting
Motor
capacity
setting
Motor
capacity
setting
Motor
capacity
setting
Motor
capacity
setting
Initial
Range (unit)
value
0.50
0.00~10.00(Hz)
0~2000(ms)
36
10ms
・・・
60ms
For parameter configuration
Manual torque boost adjustment
Code/Name
Hb140
Manual torque
boost operational mode
selection, 1st-motor
Hb141
Manual torque
boost value, 1st-motor
Hb142
Manual torque
boost Peak speed, 1st-motor
・In the manual boost operation mode only forward or
reverse boost can be selected.
・Example [Hb140]=02
Output voltage (%)
[Hb141]
Reverse
Base frequency (100%)
Eco Drive function
Code/Name
Hb145
Eco drive enable,
1st-motor
Hb146
Eco drive response
adjustment, 1st-motor
・In V/f control, if the energy saving operations is enabled,
enters an energy saving control.
4-44
[Hb140]~[Hb146]
Initial
Range (unit)
value
00(Disabled)/
01(Enabled)/
01
02(Only forward)/
03(Only reverse)
0.0~20.0(%)
0.0
0.0~50.0(%)
0.0
100
Output
Forward
frequency
[Hb142]
Base frequency (100%)
Initial
Range (unit)
value
00(Disable)/
00
01(Enable)
0~100(%)
50