Window Meanings

Table 13
WIN#
Read/ Write
000
R/W
001
R/W
008
R/W
100
R/W
101
R/W
102
R/W
103
R/W
104
R/W
105
R/W
106
R/W
108
R/W
110
R/W
111
R/W
117
R/W
Agilent TwisTorr Medium-TMP Rack Controller User Manual
Type
Meaning
L
Start/Stop (in remote mode the
window is a read only)
Low Speed Activation command
L
L
Remote or Serial configuration
Soft Start
L
(write only in Stop condition)
Set Point type
N
N
Set Point threshold (expressed in Hz, mA or s)
N
Set Point delay: time between the pump start
and the set point check (seconds)
Set Point signal activation type: the signal
L
can be "high level active" or "low level active"
N
Set point hysteresis
(in % of threshold)
L
Cooling agent
Baud Rate
N
Interlock type.
L
The interlock can be checked
at start or continuously
N
Analog output type: output voltage signal
proportional to frequency or power or
temperature.
Low speed setting [Hz]
N
Admitted Values
Start = 1;
Stop = 0
0 = OFF
1 = ON
(default = 0)
Serial = 0
Remote = 1
Front Panel = 2
(default = 2)
YES = 1
NO = 0
0 = Frequency
1 = Current
2 = Time
(default = 0)
(default = 720)
0 to 99999
(default = 0)
0 = high level active;
1 = low level active
(default = 0)
0 to 100
(default = 2)
0 = AIR
1 = WATER
(default = 0)
0 = 600 bit/s
1 = 1200 bit/s
2 = 2400 bit/s
3 = 4800 bit/s
4 = 9600 bit/s
5 = 19200 bit/s
6 = 38400 bit/s
(default = 4)
Impulse = 0
Continuous = 1
(default = 1)
0 = Frequency
1 = Power
2 = Temperature
(default = 0)
680 to WIN 121
(default = 680)
173