Rough Framing - Napoleon CONTINENTAL CEFB26H Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

installation
EN
3.3

rough framing

WARNING
!
Select a location that is not prone to moisture and is located at least 36" (91.4cm) away from combustible
materials such as curtains, drapes, furniture, bedding, paper, etc.
note:
It is recommended to complete finishing of the wall before fully securing the appliance.
Once the rough framing and the finishing materials have been prepared and the power has been routed to the
right side of the recess, the appliance may be installed.
The electrical connection must be made prior to placing the appliance into position (see "electrical information"
section).
Have two people lift the appliance into position.
In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the appliance
body, it is recommended that the walls of the appliance enclosure be "finished" (i.e. drywall / sheet rock, etc.)
as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is main-
tained within the enclosure.
Wall
Wall
(or mantel base
A
A
Rough Framing
10
W415-2971 / C / 11.18.22
C
Floor
thickness)
Floor
(or mantel base
thickness)
F
B
F
B
Ref.
CEFB26H
A
B
25 1/4" (641mm)
C
D
39 3/4" (1010mm)
E
28" (710mm)
F
Will vary with floor / mantel base thickness
C
Rough Framing in a Corner
CEFB30H
7 3/4" (197mm)
29 1/4" (743mm)
19 7/8" (505mm) + F
43 3/4" (1111mm)
30 13/16" (783mm)
E
E
B
D
B
D

Advertisement

Table of Contents
loading

This manual is also suitable for:

Continental cefb30h

Table of Contents