hard-wiring installation

WARNING
!
Turn off the appliance completely and let cool before servicing. Only a qualified service person should service
and repair this electric appliance.
HARD-WIRING CONNECTION
If it is necessary to hard-wire this appliance, a qualified electrician must remove the cord connection, and wire the
appliance directly to the household wiring. The wire and power supply breaker must be rated for 120V, minimum
15 amps.
This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local
codes, with the latest edition of the National Electrical Code ANSI/NFPA 70 in the United States or the Canadian
Electrical Code CSA C22.1 in Canada.
1. Remove the 4 screws securing the cord and cover plate to the side of the firebox (Fig. 4-1).
2. Unscrew the wire nuts securing the power supply cord.
3. Install the new strain relief (supplied) (Fig. 4-2) into the new cover plate (supplied) and feed the 14/2
conductor wire through the strain relief.
4. Connect the ground/bond wires together.
5. Connect the supply N wire to the N wire in the junction box.
6. Connect L1 to L1 of the appliance.
7. With wires secured, carefully feed the wires into the firebox and re-secure the cover plate.
A
B
C
B x 1
C x 1
HARD-WIRING
BRANCHEMENT PAR CÂBLE
BLACK/
NOIR
L1
WHITE/
BLANC
N
GREEN/
VERT
G
Rear View of Appliance
L1
N
G
W385-2554
electrical information
Fig. 4-1