Omron E3Z-L User Manual page 7

Narrow-beam photoelectric sensor with built-in amplifier
Table of Contents

Advertisement

Noise
Countermeasures for noise depend on the path of noise entry, frequency components, and wave heights. Typical measures are as given in the
following table.
Type of noise
Common mode noise
(inverter noise)
Common noise
applied between the
mounting board and
the +V and 0-V
lines, respectively.
Radiant noise
Ingress of high-fre-
quency electromag-
netic waves directly
into Sensor, from
power line, etc.
Power line noise
Ingress of electromag-
netic induction from
high-voltage wires
and switching noise
from the switching
power supply
● Wiring
Cable
Unless otherwise indicated, the maximum length of cable extension is
100 m using wire that is 0.3 mm
Exceptions are indicated in Safety Precautions in individual product
information.
Cable Tensile Strength
When wiring the cable, do not subject the cable to a tension greater than
that indicated in the following table.
Cable diameter
Less than 4 mm
4 mm or greater
Note: Do not subject a shielded cable or coaxial cable to tension.
Repeated Bending
Normally, the Sensor cable should not be bent repeatedly.
(For bending-resistant cable, see
page C-4.)
Downloaded from
Elcodis.com
electronic components distributor
Before countermeasure
Noise enters from the noise source through the frame
(metal).
Sensor
Mounting block
(metal)
Noise propagates through the air from the noise source
and directly enters the Sensor.
Noise
Sensor
source
Noise enters from the power line.
Noise
Sensor
Noise
2
or greater.
Tensile strength
30 N max.
50 N max.
Attachment to Moving Parts
http://www.ia.omron.com/
Photoelectric Sensors Technical Guide
Noise intrusion path and countermeasure
(1) Ground the inverter motor (to 100 Ω or less)
(2) Ground the noise source and the power supply (0-V
side) through a capacitor (film capacitor, 0.22 μF, 630
V).
Inverter
+V
(3) Insert an insulator (plastic, rubber, etc.) between the
motor
Sensor and the mounting plate (metal).
0V
IM
Insert an insulator.
Noise
(3)
Mounting block
(metal)
• Insert a shield (copper) plate between the Sensor and
the noise source e.g., a switching power supply).
• Separate the noise source and the Sensor to a distance
where noise does not affect operation.
+V
0V
• Insert a capacitor (e.g., a film capacitor), noise filter (e.g.,
ferrite core or insulated transformer), or varistor in the
power line.
+V
0V
Separation from High Voltage (Wiring Method)
Do not lay the cables for the Sensor together with high-voltage lines
or power lines. Placing them in the same conduit or duct may cause
damage or malfunction due to induction interference. As a general
rule, wire the Sensor in a separate system, use an independent metal
conduit, or use shielded cable.
Work Required for Unconnected Leads
Unused leads for self-diagnosis outputs or other special functions
should be cut and wrapped with insulating tape to prevent contact with
other terminals.
on
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
After countermeasure
+V
Inverter motor
Sensor
0V
(2)
IM
Noise
Noise
Shield plate (copper)
Noise
Sensor
source
Insert a capacitor, etc.
+V
Sensor
Noise
0V
Power line
Noise
(1)
+V
0V
C-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

E3z-l61E3z-l81E3z-l66E3z-l86

Table of Contents