Installing/mounting

4.1

Chapter overview (transmitter)

This chapter describes how to install the wall mount housing transmitter.
Wall mount housing
The wall mount housing transmitter can be mounted either on a wall or on a pipe (with optional
pipe mount bracket), see Installation instructions (Page 20).
4.2

Installation location requirements

4.2.1

Environment

SITRANS F flowmeters with minimum IP65/NEMA 4X enclosure rating are suitable for indoor and
outdoor installations.
Process pressure and medium temperature
If applicable, make sure that specifications for rated medium temperature (T
temperature that are indicated on the device nameplate / label will not be exceeded.
Aggressive atmospheres
Ensure that the device is suitable for the application and that it is installed where there is no risk
of penetration of aggressive vapors.
Direct sunlight
Prevent the device from overheating or materials becoming brittle due to UV exposure by
protecting it from direct sunlight. Make sure that the maximum permissible ambient
temperature is not exceeded. Refer to the information in Technical specifications (Page 77).
Electrical shock hazard
May cause death or serious injury
Disconnect power before working on this product.
Upstream / Downstream
Avoid long drop lines downstream from the sensor to prevent the meter pipe from draining.
Avoid installing the sensor upstream of a free discharge in a drop line where possible.
SITRANS FST020 IP65 (NEMA 4X)
Operating Instructions, 05/2022, A5E41425845-AC
WARNING
4
) plus ambient
S
19