From now on, it will no longer be
possible to cancel the descaling
process.
Reservoir filling
1. Mix 100 g of citric acid with 650 ml of
water in a jug.
Do not use lactic acid or other
descaling agents.
2. Open the door and pull the loading drawer
out of its housing.
3. Insert the funnel provided in the loading
drawer.
88 - CLEANING AND MAINTENANCE
4. Pour in the descaling solution until the max.
level indicator light
5. At the end, remove the funnel and place the
loading drawer back in its place.
If there is too much water in the
reservoir, the excess water will drain
into the oven cavity. In this case dry with
a cloth or sponge before proceeding.
Boiler descaling function
1. Close the door
2. Press the
button to start the function.
3. Descaling starts. The heating elements are
activated for the first 10 minutes of the
process.
comes on.