INTRODUCTION
This service manual describes the latest service information
for the IC-R9500 COMMUNICATIONS RECEIVER at the
time of publication.
MODEL
VERSION FREQUENCY COVERAGE (MHz)
[USA]
[USA-01]
IC-R9500
[EUR]
[UK]
[EXP]
ORDERING PARTS
Be sure to include the following four points when ordering
replacement parts:
1. 10-digit order numbers
2. Component part number and name
3. Equipment model name and UNIT name
4. Quantity required
<SAMPLE ORDER>
1110006750 S.IC
TK14570L
8820001210 Screw 2844 screw
Addresses are provided on the inside back cover for your
convenience.
Icom, Icom Inc. and the Icom logo are registered trademarks of Icom Incorporated (Japan) in Japan, the United States, the
United Kingdom, Germany, France, Spain, Russia and/or other countries.
0.005–821.999999,
851.000000–866.999999,
896.000000–3335.000000
0.005–3335.000000
IC-R9500
RF-A UNIT
5 pieces
IC-R9500
CHASSIS
10 pieces
CAUTION
NEVER connect the receiver to an AC outlet or to a DC
power supply that uses more than specified. This will ruin
the receiver.
DO NOT apply an RF signal of more than 20 dBm (100 mW)
to the antenna connector. This could damage the receiver's
front end.
To upgrade quality any electrical or mechanical parts and
internal circuits are subject to change without notice or
obligation.
REPAIR NOTES
1. Make sure a problem is internal before disassembling
the receiver.
2. DO NOT open the receiver until the receiver is
disconnected from its power source.
3. DO NOT force any of the variable components. Turn
them slowly and smoothly.
4. DO NOT short any circuits or electronic parts. An
insulated tuning tool MUST be used for all adjustments.
5. DO NOT keep power ON for a long time when the
receiver is defective.
6. READ the instructions of test equipment throughly
before connecting equipment to the receiver.